Skip to main content

48 Laurel Road West Ingleside NSW 2101

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 0.1 kW of solar panels and a 100,000 litre rainwater tank.

Key features

Windows
Up to aluminium frames 97.6 m², timber frames 2.5 m², single glazing 4.7 m², double glazing 95.4 m²
Wall insulation
All external walls fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil/sarking; Ceiling: none; roof: foil/sarking
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Metricon.

BASIX certificate

Energy score
72 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
15 MJ/m² a year
Cooling load
15 MJ/m² a year
Bedrooms
6
Conditioned floor area
393 m²
Unconditioned floor area
58.4 m²
Site area
3,759 m²
Roof area
257 m²
Garden area
3,431 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Solar panels
0.1 kW
Rainwater tank
100,000 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 4 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 97.6 m², timber frames 2.5 m², single glazing 4.7 m², double glazing 95.4 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, AAC panel (75 mm); frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: none; roof: foil/sarking.)

Certificate 1377632S_05, issued 7 June 2024, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.3a (3.22)
Rated on
27 Nov 2023

Certificate KOGISEUCZD, issued 27 November 2023, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related