Skip to main content

39 Mary Street Beacon Hill NSW 2100

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 6.6 kW of solar panels and a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 73 against 72.

Key features

Windows
28 windows and glazed doors: VELUX FS - Fixed Skylight DG 3mm LoE 366 / 8.5mm Argon Gap / 5.36mm Clear La
Wall insulation
R2.5
Roof and ceiling insulation
Ceiling R2.5, R3.5, R6, roof Construction Insulation Reflective wrap* Waterproofing Membrane No Added Insulation, No air Gap, medium colour
Hot water
Gas instantaneous with a performance of 5 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
73 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
14 MJ/m² a year
Cooling load
16 MJ/m² a year
Bedrooms
4
Conditioned floor area
397.4 m²
Unconditioned floor area
65.4 m²
Site area
836 m²
Roof area
365 m²
Garden area
336 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 5 stars
Solar panels
6.6 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 138.2 m², single glazing 7.3 m², double glazing 130.9 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (foil-foam composite board)
  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: timber - H2 treated softwood (foil-foam composite board)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: timber - H2 treated softwood (foil-foam composite board)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: suspended floor above garage, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: concrete panel/plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (fibreglass batts or roll)
  • External garage wall: concrete panel/plasterboard; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1837565S, issued 16 March 2026, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
BERS Pro v5.2.6 (3.23)
Rated on
16 Mar 2026
Wall insulation
R2.5
Ceiling insulation
R2.5, R3.5, R6
Floor insulation
R2.5, R1.9
LED downlights
86
All glazing by direction
N 35.8 m², E 34.7 m², S 55.9 m², W 12 m²

Roof

  • Construction Insulation Reflective wrap* Waterproofing Membrane No Added Insulation, No air Gap, medium colour
  • Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, medium colour

Window types

  • VEL-011-01 W VELUX FS - Fixed Skylight DG 3mm LoE 366 / 8.5mm Argon Gap / 5.36mm Clear La: U-value 2.6, SHGC 0.24

Window schedule

  • 001 D01: 2,400 × 3,562 mm facing E
  • 001 D02: 2,400 × 770 mm facing E
  • 001 D03: 2,400 × 5,000 mm facing S
  • 001 D04: 2,400 × 1,330 mm facing S
  • Gym VAN-004-003-001 W01: 600 × 4,331 mm facing W
  • Lower Bath VAN-004-003-001 W02: 600 × 1,500 mm facing W
  • Outdoor Sauna ALM-002-01 A D05: 2,360 × 720 mm facing E
  • 001 D06: 2,500 × 1,800 mm facing N
  • 001 W05: 2,250 × 3,240 mm facing E
  • 001 W06: 2,250 × 3,240 mm facing N
  • 001 D08: 2,500 × 5,300 mm facing S
  • 001 D09: 2,500 × 5,300 mm facing S
  • 001 W04: 1,600 × 1,800 mm facing E
  • Bath G VAN-004-008-001 W03: 1,500 × 900 mm facing E
  • 001 D07: 2,500 × 3,336 mm facing N
  • 001 D10: 2,500 × 2,300 mm facing W
  • Pantry VAN-004-003-001 W07: 2,300 × 900 mm facing S
  • 001 W09: 2,250 × 1,800 mm facing N
  • 001 W19: 1,900 × 3,240 mm facing E
  • 001 W08: 2,250 × 1,800 mm facing N
  • Bed 2 Ens VAN-004-008-001 W15: 1,500 × 900 mm facing W
  • 001 W10: 2,250 × 2,140 mm facing N
  • Bedroom 1 VAN-004-008-001 W10: 2,250 × 600 mm facing N
  • Bedroom 1 VAN-004-008-001 W10: 2,250 × 600 mm facing N
  • Bed 1 Ens VAN-004-008-001 W11: 900 × 1,520 mm facing E
  • Master Bedroom VAN-004-008-001 W13: 900 × 3,900 mm facing E
  • 001 D11: 2,500 × 4,840 mm facing S
  • Master Ens VAN-004-008-001 W14: 1,500 × 900 mm facing W

Certificate 0012844221, issued 16 March 2026, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related