North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
389 Pittwater Road North Manly NSW 2100
BASIX certificate and NatHERS rating
Finding the block on the map…
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 2 kW of solar panels and a 2,500 litre rainwater tank. It beat its BASIX energy and water targets, scoring 76 against 72 for energy and 43 against 40 for water.
Key features
- Windows
- Up to aluminium frames 60.9 m², single glazing 60.9 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric instantaneous
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 76 (target 72)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- -22
- Heating load
- 17 MJ/m² a year
- Cooling load
- 13 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 263.1 m²
- Unconditioned floor area
- 11.7 m²
- Site area
- 459 m²
- Roof area
- 160 m²
- Garden area
- 150 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric instantaneous
- Solar panels
- 2 kW
- Rainwater tank
- 2,500 litres
- Fixtures
- Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 60.9 m², single glazing 60.9 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: suspended floor above open subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1829663S, issued 20 January 2026, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 20 Jan 2026
Certificate NOLKHZKKCU, issued 20 January 2026, from the council's DA documents. Verify this certificate
Is this your home? Ask us to remove these details.