This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to a 1,500 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 48 against 40.

Key features

Windows
8 windows and glazed doors: VELUX FS - Fixed Skylight DG 3mm LoE 366 / 8.5mm Argon Gap / 5.36mm Clear La
Wall insulation
R2.5
Roof and ceiling insulation
Ceiling R6, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
Hot water
Gas instantaneous with a performance of 5 stars
Air conditioning and heating
1-phase airconditioning, non ducted (living area and bedroom)

BASIX certificate

Energy score
68 (target 68)
Water score
48 (target 40)
Thermal performance
Pass
Materials score
-5
Heating load
14 MJ/m² a year
Cooling load
15 MJ/m² a year
Bedrooms
2
Conditioned floor area
53.4 m²
Unconditioned floor area
4.3 m²
Site area
651 m²
Roof area
74 m²
Garden area
20 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 5 stars
Rainwater tank
1,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 13.5 m², double glazing 13.5 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • External garage wall: concrete panel/plasterboard; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1796669S, issued 22 May 2025, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
BERS Pro v5.2.4 (3.23)
Rated on
22 May 2025
Wall insulation
R2.5
Ceiling insulation
R6
Floor insulation
R2.5, R1.9
LED downlights
15
Living room glazing by direction
N 3.7 m², E 1.1 m²
All glazing by direction
N 3.7 m², E 2.6 m², S 6.7 m², W 1.1 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour

Window types

  • VEL-011-01 W VELUX FS - Fixed Skylight DG 3mm LoE 366 / 8.5mm Argon Gap / 5.36mm Clear La: U-value 2.6, SHGC 0.24

Window schedule

  • Kitchen/Living ALM-002-01 A: 1,100 × 1,800 mm facing N
  • Kitchen/Living ALM-001-01 A W9: 2,100 × 800 mm facing N
  • Kitchen/Living ALM-002-01 A W8: 600 × 1,800 mm facing E
  • Bath ALM-001-01 A W7: 600 × 800 mm facing E
  • Bedroom 1 ALM-002-01 A W12: 600 × 1,800 mm facing E
  • Bedroom 1 ALM-002-01 A W10: 1,600 × 2,100 mm facing S
  • Bedroom 2 ALM-002-01 A W5: 1,600 × 2,100 mm facing S
  • Bedroom 2 ALM-002-01 A W4: 600 × 1,800 mm facing W

Certificate 0011938537, issued 22 May 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate (alterations and additions), certificate A1796667, issued 22 May 2025

BASIX certificate (alterations and additions)

This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.

LED lighting
Yes

Construction and insulation

  • Concrete slab on ground floor (no added insulation)
  • Suspended floor with enclosed subfloor: framed (R0.7). R0.60 (down) (or R1.30 including construction) N/A
  • Floor above existing dwelling or building (no added insulation)
  • External wall: brick veneer R1.16 (or R1.70 including construction)
  • External wall: framed (weatherboard, fibro, metal clad) R1.30 (or R1.70 including construction)
  • Internal wall shared with garage: other/ undecided (no added insulation)
  • Flat ceiling, pitched roof ceiling: R1.95 (up), roof: foil backed blanket (55 mm) medium (solar absorptance 0.475 - 0.70)
  • Raked ceiling, pitched/skillion roof: framed ceiling: R2.24 (up), roof: foil backed blanket (55 mm) medium (solar absorptance 0.475 - 0.70)

Certificate A1796667, issued 22 May 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related