37 Monash Parade Dee Why NSW 2099
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 6.6 kW of solar panels and a 5,648 litre rainwater tank. It beat its BASIX energy target, scoring 89 against 72.
Key features
- Windows
- Up to aluminium frames 117.1 m², timber frames 1.4 m², single glazing 13.2 m², double glazing 105.3 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric boosted solar
BASIX certificate
- Energy score
- 89 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -91
- Heating load
- 13 MJ/m² a year
- Cooling load
- 16 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 271.3 m²
- Unconditioned floor area
- 22 m²
- Site area
- 828 m²
- Roof area
- 276 m²
- Garden area
- 349 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric boosted solar
- Solar panels
- 6.6 kW
- Rainwater tank
- 5,648 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 117.1 m², timber frames 1.4 m², single glazing 13.2 m², double glazing 105.3 m²
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above open subfloor, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: external insulated façade system (EIFS); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: external insulated façade system (EIFS); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1834860S, issued 25 February 2026, from the council's DA documents.