32 Bellara Avenue North Narrabeen NSW 2101
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to a 3,500 litre rainwater tank. It beat its BASIX energy target, scoring 73 against 72.
Key features
- Windows
- Up to aluminium frames 63.5 m², single glazing 14.1 m², double glazing 49.4 m²
- Wall insulation
- Rockwool batts, roll or pump-in; Rockwool batts, roll or pump-in+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, non ducted (living area and bedroom)
BASIX certificate
- Energy score
- 73 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 20 MJ/m² a year
- Cooling load
- 9 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 212 m²
- Unconditioned floor area
- 60.8 m²
- Site area
- 1,516 m²
- Roof area
- 197 m²
- Garden area
- 1,166 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 3,500 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 63.5 m², single glazing 14.1 m², double glazing 49.4 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polyurethane)
- Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (polyurethane)
- External wall: concrete block/plasterboard; frame: no frame (rockwool batts, roll or pump-in)
- External wall: AAC veneer; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in+ foil/sarking)
- External garage wall: concrete block/plasterboard; frame: no frame (rockwool batts, roll or pump-in)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1754856S_04, issued 16 January 2025, from the council's DA documents.