Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
3 Stanley Street Mona Vale NSW 2103
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 5.2 stars out of 10. Its BASIX certificate commits it to a 2,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 53 against 50.
Key features
- Windows
- 13 windows and glazed doors: Aluminium A DG Air Fill High Solar Gain low-E -Clear
- Wall insulation
- R1.7, R3.5
- Roof and ceiling insulation
- Ceiling R2.5, R5, roof Corrugated Iron No Insulation, Only an Air Gap, medium colour
- Hot water
- Solar (electric boosted) with a performance of 41 to 45 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by Bacuss.
BASIX certificate
- Energy score
- 53 (target 50)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Heating load
- 38 MJ/m² a year
- Cooling load
- 24 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 233 m²
- Unconditioned floor area
- 17 m²
- Site area
- 564 m²
- Roof area
- 345 m²
- Garden area
- 183 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Solar (electric boosted) with a performance of 41 to 45 STCs or better
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 3 star, toilets 5 star, kitchen taps 5 star, basin taps 6 star
- LED lighting
- Yes
- Clothes line
- Yes
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Certificate 1365163S, issued 8 February 2023, from the council's DA documents.
NatHERS certificate
- Star rating
- 5.2 stars
- Rated with
- BERS Pro v4.4.1.5d (3.21)
- Rated on
- 07 Feb 2023
- Wall insulation
- R1.7, R3.5
- Ceiling insulation
- R2.5, R5
- Floor insulation
- R2.5
- Living room glazing by direction
- N 31.1 m², E 19.6 m²
- All glazing by direction
- N 31.1 m², E 31.1 m², S 7.9 m², W 29.8 m²
Roof
- Corrugated Iron No Insulation, Only an Air Gap, medium colour
- Concrete No Insulation, Only an Air Gap, medium colour
- Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R0.7, medium colour
Window types
- ALM-003-03 A Aluminium A DG Air Fill High Solar Gain low-E -Clear: U-value 4.3, SHGC 0.47
Window schedule
- Kitchen/Living, window ALM-003-03 A: 2,700 × 950 mm facing E
- Kitchen/Living, window ALM-003-03 A: 2,700 × 950 mm facing E
- Kitchen/Living, window ALM-003-03 A: 2,700 × 11,520 mm facing N
- Entry, window ALM-003-03 A: 2,700 × 610 mm facing E
- Master Bedroom, window ALM-003-03 A: 2,700 × 950 mm facing S
- Master Bedroom, window ALM-003-03 A: 2,700 × 950 mm facing S
- Master Bedroom, window ALM-003-03 A: 2,700 × 4,300 mm facing W
- Ensuite Master, window ALM-003-03 A: 2,700 × 1,100 mm facing W
- Living Study, window ALM-003-03 A: 2,800 × 5,170 mm facing E
- Bedroom 2, window ALM-003-03 A: 2,800 × 3,500 mm facing E
- Ensuite 2, window ALM-003-03 A: 2,000 × 1,400 mm facing S
- Bedroom 3, window ALM-003-03 A: 2,800 × 2,800 mm facing W
- Bedroom 4, window ALM-003-03 A: 2,800 × 2,630 mm facing W
Certificate 0008399461, issued 7 February 2023, from the council's DA documents. Verify this certificate