Skip to main content

3 Knight Street Warriewood NSW 2102

Finding the block on the map…

BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to 1 kW of solar panels and a 2,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 80 against 72 for energy and 44 against 40 for water.

Key features

Windows
Up to aluminium frames 80 m², double glazing 80 m²
Wall insulation
All external walls fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil/sarking
Hot water
Electric boosted solar with a performance of 15 to 20 STCs or better
Air conditioning and heating
1-phase airconditioning, non ducted (living area and bedroom)

Built by Avjennings Housings N.s.w.

BASIX certificate

Energy score
80 (target 72)
Water score
44 (target 40)
Thermal performance
Pass
Materials score
-22
Heating load
16 MJ/m² a year
Cooling load
14 MJ/m² a year
Bedrooms
4
Conditioned floor area
272.8 m²
Unconditioned floor area
6.5 m²
Site area
1,174 m²
Roof area
248 m²
Garden area
310 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric boosted solar with a performance of 15 to 20 STCs or better
Solar panels
1 kW
Rainwater tank
2,000 litres
Fixtures
Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 80 m², double glazing 80 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground (polystyrene)
  • Floor: suspended floor above open subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, 30% cement substitute (polystyrene)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1733683S, issued 29 January 2024, from the council's DA documents.