29 Hill Street Balgowlah NSW 2093

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 5.7 stars out of 10. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 88 against 50 for energy and 48 against 40 for water.

Key features

Windows
19 windows and glazed doors: Aluminium B DG Air Fill Clear-Clear; Aluminium A DG Air Fill Clear-Clear; Al Thermally Broken B DG Air Fill Clear- Clear and 1 more types
Wall insulation
R2.5
Roof and ceiling insulation
Ceiling R4, R2.5, roof Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour

BASIX certificate (multi dwelling)

This BASIX certificate covers more than one dwelling on the lot, such as a house and a granny flat, so some of its numbers are for the whole development.

Energy score
88 (target 50)
Water score
48 (target 40)
Thermal performance
Pass
Site area
539.5 m²
Roof area
225 m²
Climate zone
NatHERS climate zone 56
Clothes line
Yes

Certificate 1292054M, issued 22 March 2022, from the council's DA documents.

NatHERS certificate

Star rating
5.7 stars
Rated with
BERS Pro v4.4.1.5 (3.21)
Rated on
22 Mar 2022
Wall insulation
R2.5
Ceiling insulation
R4, R2.5
Floor insulation
R2.5
Living room glazing by direction
N 7.2 m², E 6.2 m², W 10.4 m²
All glazing by direction
N 19.8 m², E 11.4 m², W 26.6 m²

Roof

  • Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour

Window types

  • ALM-004-01 A Aluminium B DG Air Fill Clear-Clear: U-value 4.8, SHGC 0.59
  • ALM-003-01 A Aluminium A DG Air Fill Clear-Clear: U-value 4.8, SHGC 0.51
  • ATB-004-01 B Al Thermally Broken B DG Air Fill Clear- Clear: U-value 3.6, SHGC 0.54
  • ATB-003-01 B Al Thermally Broken A DG Air Fill Clear- Clear: U-value 3.6, SHGC 0.47

Window schedule

  • Kitchen/Living, window ALM-004-01 A: 1,350 × 2,450 mm facing N
  • Kitchen/Living, window ALM-004-01 A: 1,350 × 750 mm facing E
  • Kitchen/Living, window ALM-004-01 A: 1,450 × 2,650 mm facing N
  • Kitchen/Living, window ALM-003-01 A: 2,400 × 1,640 mm facing E
  • Kitchen/Living, window ALM-004-01 A: 2,400 × 510 mm facing E
  • Kitchen/Living, window ALM-003-01 A: 2,400 × 4,330 mm facing W
  • Guest Multi, window ALM-004-01 A: 2,400 × 510 mm facing W
  • Guest Multi, window ALM-003-01 A: 2,400 × 1,640 mm facing W
  • Guest Multi, window ALM-004-01 A: 1,450 × 1,750 mm facing N
  • Staircse, window ALM-004-01 A: 1,350 × 750 mm facing E
  • Staircse, window ALM-004-01 A: 1,350 × 2,650 mm facing N
  • Bedroom 1, window ALM-003-01 A: 900 × 1,750 mm facing N
  • Bedroom 1, window ALM-004-01 A: 1,350 × 1,950 mm facing E
  • Bath, window ALM-004-01 A: 1,350 × 1,750 mm facing W
  • Bedroom 2, window ALM-004-01 A: 1,350 × 1,150 mm facing E
  • Bedroom 2, window ALM-003-01 A: 900 × 1,750 mm facing N
  • Master Bedroom, window ALM-004-01 A: 2,400 × 3,600 mm facing W
  • Master Bedroom, window ALM-003-01 A: 900 × 2,650 mm facing N
  • ENS, window ALM-004-01 A: 1,200 × 850 mm facing N

Certificate 0007146376, issued 22 March 2022, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related