North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
27 Redman Road Dee Why NSW 2099
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to a 900 litre rainwater tank. It beat its BASIX energy target, scoring 77 against 72.
Key features
- Windows
- Up to aluminium frames 86.7 m², single glazing 8.7 m², double glazing 78 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 77 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -12
- Heating load
- 11 MJ/m² a year
- Cooling load
- 17 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 196.8 m²
- Unconditioned floor area
- 14.4 m²
- Site area
- 929 m²
- Roof area
- 93 m²
- Garden area
- 100 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Rainwater tank
- 900 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 86.7 m², single glazing 8.7 m², double glazing 78 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 5 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (not specified)
- Floor: suspended floor above open subfloor, treated softwood; frame: timber - untreated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - untreated softwood (no added insulation)
- External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1777977S_02, issued 9 April 2025, from the council's DA documents.