Skip to main content

27 Peronne Avenue Clontarf NSW 2093

BASIX certificate and NatHERS rating

Finding the block on the map…

This home's BASIX certificate commits it to 10 kW of solar panels and a 20,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 94 against 72 for energy and 45 against 40 for water.

Key features

Windows
Up to aluminium frames 171.6 m², double glazing 171.6 m²
Wall insulation
Fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: none; Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Electric heat pump
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
94 (target 72)
Water score
45 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
13 MJ/m² a year
Cooling load
14 MJ/m² a year
Bedrooms
4
Conditioned floor area
305.1 m²
Unconditioned floor area
41 m²
Site area
811 m²
Roof area
226 m²
Garden area
350 m²
Climate zone
NatHERS climate zone 1
Hot water
Electric heat pump
Solar panels
10 kW
Rainwater tank
20,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 171.6 m², double glazing 171.6 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (not specified)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (not specified)
  • Garage floor: concrete - suspended; frame: no frame (not specified)
  • External wall: concrete panel/plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • External wall: framed (metal clad); frame: timber - untreated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - untreated softwood (not specified)
  • Internal wall: 200 mm AAC block; frame: timber - untreated softwood (not specified)
  • Ceiling and roof: flat ceiling / pitched roof, concrete - plasterboard internal, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: none.)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1729652S_02, issued 19 February 2024, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related