26 Seaview Avenue Curl Curl NSW 2096
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 1 kW of solar panels and a 2,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 86 against 68 for energy and 47 against 40 for water.
Key features
- Windows
- Up to aluminium frames 23.6 m², double glazing 23.6 m²
- Wall insulation
- All external walls not specified
- Roof and ceiling insulation
- Ceiling: none; roof: foil/sarking
- Hot water
- Electric heat pump
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Above Building.
BASIX certificate
- Energy score
- 86 (target 68)
- Water score
- 47 (target 40)
- Thermal performance
- Pass
- Materials score
- -10
- Heating load
- 8 MJ/m² a year
- Cooling load
- 14 MJ/m² a year
- Bedrooms
- 1
- Conditioned floor area
- 48.9 m²
- Unconditioned floor area
- 4 m²
- Site area
- 506 m²
- Roof area
- 38 m²
- Climate zone
- NatHERS climate zone 1
- Hot water
- Electric heat pump
- Solar panels
- 1 kW
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 23.6 m², double glazing 23.6 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - untreated softwood (no added insulation)
- External wall: brick veneer; frame: timber - untreated softwood. all external walls not specified
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Internal wall: cavity brick wall; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: none; roof: foil/sarking.)
Certificate 1751849S, issued 17 June 2024, from the council's DA documents.
Other certificates for this address
BASIX certificate (alterations and additions), certificate A1751670_03, issued 18 June 2024
BASIX certificate (alterations and additions)
This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.
- LED lighting
- Yes
Construction and insulation
- Concrete slab on ground floor (no added insulation)
- Suspended floor with enclosed subfloor: framed (R0.7). R0.60 (down) (or R1.30 including construction) N/A
- Suspended floor above garage: framed (R0.7) (no added insulation)
- Floor above existing dwelling or building (no added insulation)
- External wall: brick veneer R1.16 (or R1.70 including construction)
- External wall: framed (weatherboard, fibro, metal clad) R1.30 (or R1.70 including construction)
- Internal wall shared with garage: plasterboard (R0.36)
- Flat ceiling, pitched roof ceiling: R3.00 (up), roof: foil/sarking medium (solar absorptance 0.475 - 0.70)
- Raked ceiling, pitched/skillion roof: framed ceiling: R3.00 (up), roof: foil/sarking medium (solar absorptance 0.475 - 0.70)
Certificate A1751670_03, issued 18 June 2024, from the council's DA documents.