North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
2 Wandeen Road Clareville NSW 2107
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 73 against 72 for energy and 42 against 40 for water.
Key features
- Windows
- Up to aluminium frames 80.4 m², double glazing 80.4 m²
- Wall insulation
- No added insulation; Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, non ducted (living area and bedroom)
BASIX certificate
- Energy score
- 73 (target 72)
- Water score
- 42 (target 40)
- Materials score
- -19
- Heating load
- 15 MJ/m² a year
- Cooling load
- 14 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 202.9 m²
- Unconditioned floor area
- 28.8 m²
- Site area
- 793 m²
- Roof area
- 181 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 80.4 m², double glazing 80.4 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: timber - H2 treated softwood (not specified)
- Floor: suspended floor above open subfloor, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
- External wall: cavity brick; frame: no frame (no added insulation)
- External wall: framed (metal clad); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: concrete block/plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1846089S_02, issued 19 August 2026, from the council's DA documents.