Skip to main content

2 Wandeen Road Clareville NSW 2107

BASIX certificate and NatHERS rating

Finding the block on the map…

This home's BASIX certificate commits it to a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 73 against 72 for energy and 42 against 40 for water.

Key features

Windows
Up to aluminium frames 80.4 m², double glazing 80.4 m²
Wall insulation
No added insulation; Fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Air conditioning and heating
1-phase airconditioning, non ducted (living area and bedroom)

BASIX certificate

Energy score
73 (target 72)
Water score
42 (target 40)
Materials score
-19
Heating load
15 MJ/m² a year
Cooling load
14 MJ/m² a year
Bedrooms
3
Conditioned floor area
202.9 m²
Unconditioned floor area
28.8 m²
Site area
793 m²
Roof area
181 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 80.4 m², double glazing 80.4 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: timber - H2 treated softwood (not specified)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
  • External wall: cavity brick; frame: no frame (no added insulation)
  • External wall: framed (metal clad); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: concrete block/plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1846089S_02, issued 19 August 2026, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related