19 Fairlight Crescent Fairlight NSW 2094

BASIX certificate and NatHERS rating

Finding the block on the map…

Key features

Wall insulation
Solar absorptance 0.48-0.7
Hot water
Gas instantaneous with a performance of 6.5 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
68 (target 68)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
7
Bedrooms
1
Conditioned floor area
45 m²
Site area
220 m²
Roof area
45 m²
Hot water
Gas instantaneous with a performance of 6.5 stars
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • External wall: concrete panel/ plasterboard; frame: light steel frame. all external walls 3.15 (or 3.50 including construction) with one of the measures to address thermal bridging;fibreglass batts or roll • Install reflective foil outside the frame to create a minimum 20 mm reflective airspace between frame and veneer, or • Install continuous insulation layer with at least R0.3 on the inside or outside of the frame wall colour: Medium (solar absorptance 0.48-0.7)

Certificate 1829530S_04, issued 22 January 2026, from the council's DA documents.

Other certificates for this address

BASIX certificate (alterations and additions), certificate A1829611_04, issued 7 August 2026

BASIX certificate (alterations and additions)

This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.

LED lighting
Yes

Construction and insulation

  • Concrete slab on ground floor (no added insulation)
  • Suspended floor with open subfloor: concrete (R0.6). R0.9 (down) (or R1.50 including construction) N/A
  • Suspended floor with enclosed subfloor: concrete (R0.6). R0.70 (down) (or R1.30 including construction) N/A
  • External wall: concrete panel/ plasterboard (concrete: 150 mm) R1.39 (or R1.70 including construction)
  • External wall: brick veneer R1.16 (or R1.70 including construction)
  • External wall: framed (weatherboard, fibro, metal clad) R1.30 (or R1.70 including construction)
  • Flat ceiling, pitched roof ceiling: R3.00 (up), roof: foil/sarking medium (solar absorptance 0.475 - 0.70)
  • Flat ceiling, flat roof: concrete/ plasterboard internal ceiling: R3.00 (up), roof: foil/sarking medium (solar absorptance 0.475 - 0.70)

Certificate A1829611_04, issued 7 August 2026, from the council's DA documents.