North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
18 Maxwell Parade Frenchs Forest NSW 2086
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 3 kW of solar panels and a 4,000 litre rainwater tank. It beat its BASIX energy target, scoring 73 against 72.
Key features
- Windows
- Up to aluminium frames 183.8 m², double glazing 183.8 m²
- Wall insulation
- All external walls foil-foam composite board
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Sunny Building Construction.
BASIX certificate
- Energy score
- 73 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 15 MJ/m² a year
- Cooling load
- 15 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 286.5 m²
- Unconditioned floor area
- 24.7 m²
- Site area
- 602 m²
- Roof area
- 216 m²
- Garden area
- 279 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 3 kW
- Rainwater tank
- 4,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 183.8 m², double glazing 183.8 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (foil-foam composite board)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: cavity brick; frame: no frame. all external walls foil-foam composite board
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1759707S, issued 13 August 2024, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1759645S, issued 13 August 2024
BASIX certificate
- Energy score
- 72 (target 72)
- Water score
- 44 (target 40)
- Thermal performance
- Pass
- Materials score
- -80
- Heating load
- 10 MJ/m² a year
- Cooling load
- 11 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 346.4 m²
- Unconditioned floor area
- 9.1 m²
- Site area
- 601 m²
- Roof area
- 268 m²
- Garden area
- 269 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 7 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 134 m², single glazing 11.5 m², double glazing 122.5 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: cavity brick; frame: no frame. all external walls foil-foam composite board
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1759645S, issued 13 August 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.