North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
15 Tarra Crescent Dee Why NSW 2099
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to a 3,000 litre rainwater tank. It beat its BASIX water target, scoring 46 against 40.
Key features
- Windows
- Up to aluminium frames 73.5 m², double glazing 73.5 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Amde Construction.
BASIX certificate
- Energy score
- 72 (target 72)
- Water score
- 46 (target 40)
- Thermal performance
- Pass
- Materials score
- -30
- Heating load
- 19 MJ/m² a year
- Cooling load
- 11 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 302.9 m²
- Unconditioned floor area
- 28.5 m²
- Site area
- 557 m²
- Roof area
- 298 m²
- Garden area
- 225 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 73.5 m², double glazing 73.5 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: suspended floor above open subfloor, fibre cement; frame: timber - H2 treated softwood (polystyrene)
- Floor: above habitable rooms or mezzanine, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (polystyrene)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1770928S_02, issued 18 November 2024, from the council's DA documents.