Skip to main content

15 Raven Circuit Warriewood NSW 2102

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 6.6 kW of solar panels and a 1,066 litre rainwater tank. It beat its BASIX energy target, scoring 90 against 72.

Key features

Windows
Up to aluminium frames 38.1 m², timber frames 2.9 m², single glazing 2.9 m², double glazing 38.1 m²
Wall insulation
Fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by McDonald Jones Homes.

BASIX certificate

Energy score
90 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-30
Heating load
19 MJ/m² a year
Cooling load
11 MJ/m² a year
Bedrooms
5
Conditioned floor area
145.2 m²
Unconditioned floor area
11.9 m²
Site area
243 m²
Roof area
145 m²
Garden area
100 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
6.6 kW
Rainwater tank
1,066 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 38.1 m², timber frames 2.9 m², single glazing 2.9 m², double glazing 38.1 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: suspended floor above open subfloor, particle board; frame: light steel frame (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, particle board; frame: light steel frame (fibreglass batts or roll)
  • Floor: suspended floor above garage, particle board; frame: light steel frame (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: light steel frame (fibreglass batts or roll)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - hardwood predominant incl. glue laminated beams (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: light steel frame (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: light steel frame (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1802439S_03, issued 24 October 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
24 Oct 2025

Certificate JX1C6S90G2-01, issued 24 October 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

NatHERS certificate, certificate JX1C6S90G2, issued 2 July 2025

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
2 Jul 2025

Certificate JX1C6S90G2, issued 2 July 2025, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.