12 Cooleena Road Elanora Heights NSW 2101
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 6.6 kW of solar panels and an 8,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 100 against 72.
Key features
- Windows
- 26 windows and glazed doors
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R7, R4, roof Construction Insulation Reflective wrap* Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, medium colour
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 100 (target 72)
- Water score
- 40 (target 40)
- Materials score
- -11
- Heating load
- 19 MJ/m² a year
- Cooling load
- 11 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 244 m²
- Unconditioned floor area
- 31 m²
- Site area
- 572 m²
- Roof area
- 225 m²
- Garden area
- 322 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Solar panels
- 6.6 kW
- Rainwater tank
- 8,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 6 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 59.7 m², single glazing 59.7 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1839800S_03, issued 23 July 2026, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.2.6 (3.23)
- Rated on
- 23 Jul 2026
- Wall insulation
- R2.5
- Ceiling insulation
- R7, R4
- Floor insulation
- R2.5, R2, R4
- LED downlights
- 54
- Living room glazing by direction
- N 14.4 m², E 7.8 m², S 4.2 m², W 1.3 m²
- All glazing by direction
- N 19.8 m², E 13.5 m², S 10.8 m², W 10.5 m²
Roof
- Construction Insulation Reflective wrap* Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, medium colour
Window schedule
- Kitchen/Living STG-005-015-001 W7: 2,000 × 2,600 mm facing N
- Kitchen/Living STG-004-031-001 W8: 2,000 × 4,600 mm facing N
- Kitchen/Living STG-002-019-001 W9: 2,100 × 1,000 mm facing E
- Kitchen/Living STG-002-019-001 W10: 2,100 × 1,000 mm facing E
- Kitchen/Living STG-077-003-001 W6: 700 × 1,800 mm facing W
- LDRY STG-005-002-001 W11: 2,400 × 1,450 mm facing E
- B'PTRY STG-077-003-001 W5: 700 × 1,000 mm facing W
- Guest Bed STG-002-019-001: 2,100 × 900 mm facing W
- Guest Bed STG-002-019-001: 2,100 × 900 mm facing W
- PDR STG-007-003-001 W25: 400 × 1,200 mm facing W
- Study STG-002-019-001 W38: 2,100 × 925 mm facing S
- Study STG-002-019-001: 2,100 × 925 mm facing S
- Bedroom 2 STG-007-016-001 W19: 1,000 × 1,800 mm facing N
- Bedroom 2 STG-007-016-001 W36: 1,000 × 1,800 mm facing W
- Bath STG-007-003-001 W32: 700 × 2,100 mm facing W
- ENS STG-007-003-001 W16: 700 × 1,500 mm facing W
- Bedroom 1 STG-002-019-001 W12: 1,500 × 925 mm facing S
- Bedroom 1 STG-002-019-001 W13: 1,500 × 925 mm facing S
- Bedroom 3 STG-007-016-001 W20: 1,000 × 1,800 mm facing N
- Bedroom 4 STG-007-016-001 W21: 1,000 × 1,800 mm facing N
- Upper Living STG-002-019-001 W15: 1,800 × 1,000 mm facing E
- Upper Living STG-002-019-001 W31: 1,800 × 1,000 mm facing E
- Upper Living STG-002-019-001 W34: 1,500 × 925 mm facing S
- Upper Living STG-002-019-001 W35: 1,500 × 925 mm facing S
- Upper Living STG-002-019-001 W33: 1,500 × 925 mm facing S
- Upper Hall STG-077-003-001 W37: 1,500 × 1,500 mm facing E
Certificate 0012882403-01, issued 23 July 2026, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1839800S_02, issued 30 March 2026
BASIX certificate
- Energy score
- 100 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -11
- Heating load
- 16 MJ/m² a year
- Cooling load
- 14 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 244 m²
- Unconditioned floor area
- 31 m²
- Site area
- 572 m²
- Roof area
- 225 m²
- Garden area
- 322 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Solar panels
- 6.6 kW
- Rainwater tank
- 8,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 6 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 59.7 m², single glazing 59.7 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1839800S_02, issued 30 March 2026, from the council's DA documents.
NatHERS certificate, certificate 0012882403, issued 30 March 2026
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.2.6 (3.23)
- Rated on
- 30 Mar 2026
- Wall insulation
- R2.5
- Ceiling insulation
- R4, R7
- Floor insulation
- R2.5, R2, R4
- LED downlights
- 54
- Living room glazing by direction
- N 14.4 m², E 7.8 m², S 7.9 m², W 1.3 m²
- All glazing by direction
- N 19.8 m², E 13.5 m², S 16.1 m², W 10.4 m²
Roof
- Construction Insulation Reflective wrap* Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, medium colour
Window schedule
- Kitchen/Living STG-005-015-001 W7: 2,000 × 2,600 mm facing N
- Kitchen/Living STG-005-015-001 W8: 2,000 × 4,600 mm facing N
- Kitchen/Living STG-002-019-001 W9: 2,100 × 1,000 mm facing E
- Kitchen/Living STG-002-019-001 W10: 2,100 × 1,000 mm facing E
- Kitchen/Living STG-077-003-001 W6: 700 × 1,800 mm facing W
- LDRY STG-005-002-001 W11: 2,400 × 1,450 mm facing E
- B'PTRY STG-077-003-001 W5: 700 × 1,000 mm facing W
- Guest Bed STG-002-019-001 W3: 2,100 × 900 mm facing W
- Guest Bed STG-002-019-001 W4: 2,100 × 900 mm facing W
- PDR STG-007-003-001 W25: 400 × 1,200 mm facing W
- Study STG-002-019-001 W1: 2,100 × 925 mm facing S
- Study STG-002-019-001 W2: 2,100 × 925 mm facing S
- Bedroom 2 STG-007-016-001 W19: 1,000 × 1,800 mm facing N
- Bedroom 2 STG-007-016-001 W18: 1,000 × 1,800 mm facing W
- Bath STG-002-024-001 W17: 1,300 × 900 mm facing W
- ENS STG-002-024-001 W16: 1,300 × 900 mm facing W
- Bedroom 1 STG-002-019-001 W14: 1,500 × 1,000 mm facing S
- Bedroom 1 STG-002-019-001 W12: 1,500 × 925 mm facing S
- Bedroom 1 STG-002-019-001 W13: 1,500 × 925 mm facing S
- Bedroom 3 STG-007-016-001 W20: 1,000 × 1,800 mm facing N
- Bedroom 4 STG-007-016-001 W21: 1,000 × 1,800 mm facing N
- Upper Living STG-002-019-001 W23: 1,800 × 1,000 mm facing E
- Upper Living STG-002-019-001 W24: 1,800 × 1,000 mm facing E
- Upper Living STG-005-015-001 W15: 2,200 × 3,600 mm facing S
- Upper Hall STG-077-003-001 W22: 1,500 × 1,500 mm facing E
Certificate 0012882403, issued 30 March 2026, from the council's DA documents. Verify this certificate