North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
12 Capua Place Avalon Beach NSW 2107
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 2,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 48 against 40.
Key features
- Windows
- 11 windows and glazed doors: VELUX VS - Ventilating Skylight DG 3mm LoE 366 / 8.5mm Argon Gap / 5.36mm Clear La
- Wall insulation
- R2.7, R2.5
- Roof and ceiling insulation
- Ceiling R3.1, R6, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
- Hot water
- Gas instantaneous with a performance of 6 stars
BASIX certificate
- Energy score
- 68 (target 68)
- Water score
- 48 (target 40)
- Thermal performance
- Pass
- Materials score
- -19
- Heating load
- 18 MJ/m² a year
- Cooling load
- 12 MJ/m² a year
- Bedrooms
- 1
- Conditioned floor area
- 44.2 m²
- Unconditioned floor area
- 4.1 m²
- Site area
- 771 m²
- Roof area
- 79 m²
- Garden area
- 50 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 20.2 m², single glazing 2.2 m², double glazing 18 m²
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polystyrene)
- Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (polystyrene)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1762283S_02, issued 14 February 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.2.2 (3.23)
- Rated on
- 30 Aug 2024
- Wall insulation
- R2.7, R2.5
- Ceiling insulation
- R3.1, R6
- Floor insulation
- R2.7, R2.5, R2.3, R3.1
- LED downlights
- 12
- Living room glazing by direction
- SW 11.3 m², NW 4 m²
- All glazing by direction
- N 2 m², NE 0.4 m², SW 13.1 m², NW 7 m²
Roof
- Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
- Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, medium colour
Window types
- VEL-010-01 W VELUX VS - Ventilating Skylight DG 3mm LoE 366 / 8.5mm Argon Gap / 5.36mm Clear La: U-value 2.5, SHGC 0.21
Window schedule
- Entry AWS-090-029-001 W5: 2,000 × 500 mm facing NW
- Entry AWS-090-029-001 W4: 2,000 × 500 mm facing NW
- Entry AWS-090-029-001 W6: 2,000 × 500 mm facing NW
- Bathroom BRZ-006-009-001 W11: 600 × 700 mm facing NE
- Kitchen/Living AWS-090-029-001 W8: 450 × 4,600 mm facing SW
- Kitchen/Living AWS-062-310-001 W12: 2,050 × 4,505 mm facing SW
- Kitchen/Living AWS-090-029-001 W7: 900 × 3,300 mm facing NW
- Kitchen/Living AWS-090-029-001 W13: 2,000 × 500 mm facing NW
- Garage BRD-044-001-001 W3: 600 × 3,000 mm facing SW
- Garage A&L-001-004-001 S3: 400 × 2,500 mm facing N
- Garage A&L-001-004-001 S4: 400 × 2,500 mm facing N
Certificate 0009726928, issued 30 August 2024, from the council's DA documents. Verify this certificate
Is this your home? Ask us to remove these details.