Skip to main content

1142 Pittwater Road Collaroy NSW 2097

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 2,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 42 against 40.

Key features

Windows
33 windows and glazed doors
Wall insulation
R0.9, R2.5
Roof and ceiling insulation
Ceiling R6, R2, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
72 (target 72)
Water score
42 (target 40)
Thermal performance
Pass
Materials score
-64
Heating load
17 MJ/m² a year
Cooling load
13 MJ/m² a year
Bedrooms
6
Conditioned floor area
329.9 m²
Unconditioned floor area
21.4 m²
Site area
551 m²
Roof area
267 m²
Garden area
203 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Rainwater tank
2,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 98.9 m², single glazing 21.8 m², double glazing 77.1 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: no frame (foil-foam composite board+ foil/sarking)
  • External wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1764484S, issued 13 September 2024, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
BERS Pro v5.2.2 (3.23)
Rated on
29 Jul 2024
Wall insulation
R0.9, R2.5
Ceiling insulation
R6, R2
Floor insulation
R0.9, R2.5, R2
Living room glazing by direction
N 3.8 m², S 3.8 m², W 8.9 m²
All glazing by direction
N 21.1 m², NE 2.9 m², E 46.7 m², S 12.8 m², W 17.3 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
  • Waterproofing Membrane No Insulation, Only an Air Gap, medium colour

Window schedule

  • BED 1 AWS-003-064-001 W13: 1,200 × 2,200 mm facing N
  • GF RUMPUS VAN-004-001-001 W11: 2,100 × 700 mm facing W
  • GF RUMPUS VAN-004-001-001 W12: 2,100 × 700 mm facing W
  • GF BATH 1 AWS-007-002-001 W10: 900 × 700 mm facing W
  • LAUNDRY VAN-004-001-001 W09: 2,100 × 600 mm facing E
  • LAUNDRY AWS-018-001-001 D03: 2,100 × 900 mm facing E
  • ENTRY GF HALL AWS-067-039-001 W08 Lower: 2,600 × 1,600 mm facing S
  • BED 2 AWS-003-064-001 W01: 1,200 × 2,200 mm facing N
  • LIV KIT DIN VAN-004-001-001 W02: 2,400 × 900 mm facing N
  • LIV KIT DIN VAN-004-001-001 W03: 2,400 × 900 mm facing N
  • LIV KIT DIN VAN-004-001-001 W04: 2,400 × 900 mm facing N
  • LIV KIT DIN VAN-004-001-001 W5: 2,400 × 900 mm facing N
  • LIV KIT DIN AWS-089-058-001 D01: 2,400 × 4,000 mm facing E
  • LIV KIT DIN AWS-089-058-001 D02: 2,400 × 4,000 mm facing E
  • LIV KIT DIN AWS-067-039-001 W06: 600 × 4,000 mm facing S
  • LIV KIT DIN AWS-067-039-001 W07: 600 × 4,000 mm facing S
  • GARAGE AWS-066-007-001 EXW01: 1,416 × 643 mm facing N
  • GARAGE AWS-066-007-001 EXW02: 1,416 × 643 mm facing N
  • GARAGE AWS-066-007-001 EXW03: 1,416 × 643 mm facing N
  • BED 3 ENS AWS-007-002-001 W15: 1,500 × 700 mm facing W
  • BED 3 WIR AWS-019-042-001 D04: 2,700 × 860 mm facing W
  • BED 3 AWS-003-064-001 W16: 1,300 × 2,200 mm facing NE
  • UF WC AWS-007-002-001 W14: 1,500 × 700 mm facing W
  • LIVING UF HALL AWS-067-039-001 W17: 2,400 × 1,600 mm facing N
  • LIVING UF HALL AWS-067-039-001 W20: 2,400 × 1,600 mm facing S
  • LIVING UF HALL AWS-089-058-001 D09: 2,700 × 2,199 mm facing W
  • BED 5 ENS AWS-007-002-001 W18: 1,000 × 600 mm facing N
  • BED 5 AWS-089-058-001 D05: 2,700 × 2,700 mm facing E
  • BED 6 AWS-089-058-001 D06: 2,700 × 2,700 mm facing E
  • STUDY AWS-089-058-001 D07: 2,700 × 2,700 mm facing E
  • BED 4 AWS-003-064-001 W21: 1,500 × 1,620 mm facing E
  • BED 4 AWS-019-042-001 D08: 2,700 × 860 mm facing W
  • BED 4 ENS AWS-007-002-001 W22: 1,500 × 700 mm facing W

Certificate 0009655796, issued 29 July 2024, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related