North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
100 Hilltop Road Avalon Beach NSW 2107
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 3 kW of solar panels and a 3,500 litre rainwater tank. It beat its BASIX energy and water targets, scoring 84 against 72 for energy and 42 against 40 for water.
Key features
- Windows
- Up to aluminium frames 64.5 m², single glazing 3.8 m², double glazing 60.7 m²
- Wall insulation
- Fibreglass batts or roll; No added insulation
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket; Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Electric storage
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 84 (target 72)
- Water score
- 42 (target 40)
- Thermal performance
- Pass
- Materials score
- -81
- Heating load
- 19 MJ/m² a year
- Cooling load
- 8 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 231 m²
- Unconditioned floor area
- 3 m²
- Site area
- 1,000 m²
- Roof area
- 197 m²
- Garden area
- 615 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric storage
- Solar panels
- 3 kW
- Rainwater tank
- 3,500 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 64.5 m², single glazing 3.8 m², double glazing 60.7 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (polystyrene)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
- External wall: reverse brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: concrete block/plasterboard; frame: no frame (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: single skin masonry; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, no frame (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1757573S_03, issued 30 July 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.