North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
9 Little Alfred Street North Sydney NSW 2060
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 2 kW of solar panels and a 2,500 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 91 against 72.
Key features
- Windows
- 24 windows and glazed doors: Al Thermally Broken A DG Argon Fill High Solar; Al Thermally Broken B DG Argon Fill High Solar; Aluminium A SG Clear
- Wall insulation
- R2.5, R2.7
- Roof and ceiling insulation
- Ceiling R3, R4, R6, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
- Hot water
- Electric heat pump with a performance of 21 to 25 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 91 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -50
- Heating load
- 22 MJ/m² a year
- Cooling load
- 8 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 138 m²
- Unconditioned floor area
- 5 m²
- Site area
- 193 m²
- Roof area
- 104 m²
- Garden area
- 75 m²
- Climate zone
- NatHERS climate zone 17
- Hot water
- Electric heat pump with a performance of 21 to 25 STCs or better
- Solar panels
- 2 kW
- Rainwater tank
- 2,500 litres
- Fixtures
- Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 38 m², single glazing 2 m², double glazing 36 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (not specified)
- Floor: suspended floor above enclosed subfloor, fibre cement; frame: timber - H2 treated softwood (not specified)
- Floor: suspended floor above open subfloor, fibre cement; frame: timber - H2 treated softwood (not specified)
- Floor: above habitable rooms or mezzanine, fibre cement; frame: timber - H2 treated softwood (not specified)
- Floor: suspended floor above garage, fibre cement; frame: timber - H2 treated softwood (not specified)
- Garage floor: concrete - suspended; frame: no frame (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (not specified)
- External wall: cavity brick; frame: no frame (not specified)
- External wall: brick veneer; frame: timber - H2 treated softwood (not specified)
- External garage wall: brick veneer; frame: no frame (no added insulation)
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
Certificate 1844121S, issued 29 April 2026, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.2.6 (3.23)
- Rated on
- 29 Apr 2026
- Wall insulation
- R2.5, R2.7
- Ceiling insulation
- R3, R4, R6
- Floor insulation
- R2.5, R2.7, R2, R1.5, R3
- LED downlights
- 33
- Living room glazing by direction
- N 4.2 m², E 8.4 m², S 3.9 m², W 1 m²
- All glazing by direction
- N 6.9 m², E 20.6 m², S 7.1 m², W 3 m²
Roof
- Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
- Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R0.2, medium colour
Window types
- ATB-005-03 B Al Thermally Broken A DG Argon Fill High Solar: U-value 2.9, SHGC 0.44
- ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar: U-value 2.9, SHGC 0.51
- ALM-001-01 A Aluminium A SG Clear: U-value 6.7, SHGC 0.57
Window schedule
- Bedroom 2, window ATB-005-03 B: 1,950 × 1,220 mm facing E
- Hall/Stair LGF, window ATB-005-03 B: 1,400 × 600 mm facing S
- Kitch/Liv/Dine, window ATB-005-03 B: 2,400 × 900 mm facing N
- Kitch/Liv/Dine, window ATB-006-03 B: 1,950 × 1,045 mm facing N
- Kitch/Liv/Dine, window ATB-005-03 B: 1,950 × 500 mm facing W
- Kitch/Liv/Dine, window ATB-006-03 B: 2,400 × 3,100 mm facing E
- Kitch/Liv/Dine, window ATB-005-03 B: 1,950 × 500 mm facing E
- Kitch/Liv/Dine, window ATB-005-03 B: 1,950 × 300 mm facing S
- Kitch/Liv/Dine, window ATB-005-03 B: 1,950 × 300 mm facing S
- Kitch/Liv/Dine, window ATB-005-03 B: 1,950 × 300 mm facing S
- Kitch/Liv/Dine, window ATB-005-03 B: 2,400 × 900 mm facing S
- Bedroom 1, window ATB-005-03 B: 1,300 × 600 mm facing N
- Bedroom 1, window ATB-005-03 B: 1,300 × 600 mm facing N
- Bedroom 1, window ATB-005-03 B: 2,400 × 3,410 mm facing E
- Study, window ATB-005-03 B: 1,300 × 300 mm facing N
- Study, window ATB-005-03 B: 1,300 × 300 mm facing N
- Study, window ATB-005-03 B: 1,300 × 300 mm facing N
- Garage, window ALM-001-01 A: 1,300 × 1,220 mm facing E
- GF Hall/Laundry, window ATB-005-03 B: 1,300 × 600 mm facing S
- GF Hall/Laundry, window ATB-005-03 B: 1,300 × 600 mm facing S
- GF Hall/Laundry, window ATB-005-03 B: 1,250 × 600 mm facing W
- Bath GF, window ATB-005-03 B: 1,300 × 600 mm facing S
- Guest Bedroom, window ATB-006-03 B: 900 × 900 mm facing W
- Guest Bedroom, window ATB-005-03 B: 790 × 600 mm facing W
Certificate 0012950648, issued 29 April 2026, from the council's DA documents.
Is this your home? Ask us to remove these details.