Skip to main content

36 Bradleys Head Road Mosman NSW 2088

Finding the block on the map…

BASIX certificate and NatHERS rating

Key features

Wall insulation
Or R1.70 including construction; No added insulation; Including construction

BASIX certificate (alterations and additions)

This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.

LED lighting
Yes

Construction and insulation

  • Concrete slab on ground floor (no added insulation)
  • Suspended floor with open subfloor: concrete (R0.6). R0.9 (down) (or R1.50 including construction) N/A
  • Floor above existing dwelling or building (no added insulation)
  • External wall: brick veneer R1.16 (or R1.70 including construction)
  • External wall: cavity brick (no added insulation)
  • External wall: other/undecided R1.70 (including construction)
  • Internal wall shared with garage: other/ undecided (no added insulation)
  • Flat ceiling, pitched roof ceiling: R3.00 (up), roof: none light (solar absorptance < 0.475)
  • Raked ceiling, pitched/skillion roof: framed ceiling: R3.00 (up), roof: none light (solar absorptance < 0.475)
  • Flat ceiling, flat roof: concrete/ plasterboard internal ceiling: R3.00 (up), roof: none light (solar absorptance < 0.475)

Certificate A1830925_02, issued 8 July 2026, from the council's DA documents.

Other certificates for this address

BASIX certificate (alterations and additions), certificate A1830925, issued 30 January 2026

BASIX certificate (alterations and additions)

This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.

LED lighting
Yes

Construction and insulation

  • Concrete slab on ground floor (no added insulation)
  • Suspended floor with open subfloor: concrete (R0.6). R0.9 (down) (or R1.50 including construction) N/A
  • Floor above existing dwelling or building (no added insulation)
  • External wall: brick veneer R1.16 (or R1.70 including construction)
  • External wall: cavity brick (no added insulation)
  • External wall: other/undecided R1.70 (including construction)
  • Internal wall shared with garage: other/ undecided (no added insulation)
  • Flat ceiling, pitched roof ceiling: R3.00 (up), roof: none light (solar absorptance < 0.475)
  • Raked ceiling, pitched/skillion roof: framed ceiling: R3.00 (up), roof: none light (solar absorptance < 0.475)
  • Flat ceiling, flat roof: concrete/ plasterboard internal ceiling: R3.00 (up), roof: none light (solar absorptance < 0.475)

Certificate A1830925, issued 30 January 2026, from the council's DA documents.