Skip to main content

193 Raglan Street Mosman NSW 2088

Finding the block on the map…

BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to 2.5 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy target, scoring 73 against 72.

Key features

Windows
Up to aluminium frames 202 m², double glazing 202 m²
Wall insulation
Rockwool batts, roll or pump-in
Hot water
Electric heat pump with a performance of 21 to 25 STCs or better
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

Built by Arc Renovation & Construction.

BASIX certificate

Energy score
73 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
18 MJ/m² a year
Cooling load
10 MJ/m² a year
Bedrooms
4
Conditioned floor area
339 m²
Unconditioned floor area
28 m²
Site area
696 m²
Roof area
271 m²
Garden area
282 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric heat pump with a performance of 21 to 25 STCs or better
Solar panels
2.5 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 202 m², double glazing 202 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (foil-foam composite board)
  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: timber - H2 treated softwood (foil-foam composite board)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: timber - H2 treated softwood (foil-foam composite board)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: timber - H2 treated softwood (foil-foam composite board)
  • Garage floor: concrete slab on ground (foil-foam composite board)
  • External wall: concrete block/plasterboard; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
  • External wall: cavity brick; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
  • External garage wall: concrete block/plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: timber - H2 treated softwood (no added insulation)

Certificate 1778000S_03, issued 20 December 2024, from the council's DA documents.