Skip to main content

7 Chorley Avenue Cheltenham NSW 2119

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7.3 stars out of 10. Its BASIX certificate commits it to 8.36 kW of solar panels and a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 100 against 72 for energy and 42 against 40 for water.

Key features

Windows
85 windows and glazed doors: Timber A DG Argon Fill Low Solar Gain low-E - Clear; Timber B DG Argon Fill Low Solar Gain low-E - Clear
Wall insulation
R4, R1.7, R8.8
Roof and ceiling insulation
Ceiling R7, roof Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
Hot water
Ground source heat pump (direct exchange) only
Air conditioning and heating
Ground source heat pump (closed loop) (living area and bedroom)

Built by Hi-pac Constructions.

BASIX certificate

Energy score
100 (target 72)
Water score
42 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
9 MJ/m² a year
Cooling load
18 MJ/m² a year
Bedrooms
7
Conditioned floor area
1,127 m²
Unconditioned floor area
90 m²
Site area
2,452 m²
Roof area
834 m²
Garden area
1,268 m²
Climate zone
NatHERS climate zone 56
Hot water
Ground source heat pump (direct exchange) only
Solar panels
8.36 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
timber frames 241.2 m², double glazing 241.2 m²

Heating

  • Living area: ground source heat pump (closed loop); Energy rating: EER 3.0 - 3.5
  • Bedroom: ground source heat pump (closed loop); Energy rating: EER 3.0 - 3.5 A certificate of specifications issued by

Cooling

  • Living area: ground source heat pump (closed loop); Energy rating: EER 3.0 - 3.5
  • Bedroom: ground source heat pump (closed loop); Energy rating: EER 3.0 - 3.5 A certificate of specifications issued by

Construction and insulation

  • Floor: concrete slab on ground (not specified)
  • Garage floor: concrete slab on ground (not specified)
  • External wall: concrete block/plasterboard; frame: timber - untreated softwood (rockwool batts, roll or pump-in+ foil/sarking)
  • External wall: brick veneer; frame: timber - untreated softwood (rockwool batts, roll or pump-in+ foil/sarking)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - untreated softwood (rockwool batts, roll or pump-in+ foil/sarking)
  • External wall: cavity brick; frame: no frame (rockwool batts, roll or pump-in+ foil/sarking)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - terracotta tiles , timber - untreated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil/sarking.)

Certificate 1731748S, issued 22 December 2023, from the council's DA documents.

NatHERS certificate

Star rating
7.3 stars
Rated with
BERS Pro v5.1.6 (3.22)
Rated on
22 Dec 2023
Wall insulation
R4, R1.7, R8.8
Ceiling insulation
R7
Floor insulation
R4, R1.7, R8.8
Living room glazing by direction
N 3.5 m², NE 11.7 m², E 3.5 m², SE 15.9 m², SW 6.5 m², W 3.5 m², NW 16.8 m²
All glazing by direction
N 9.9 m², NE 42.2 m², E 8.7 m², SE 52.2 m², SW 54.8 m², W 12.5 m², NW 61 m²

Roof

  • Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
  • Roof Tiles Timber Frame Foil, No Gap, Reflective Side Down, Anti-glare Up, light colour

Window types

  • TIM-005-04 W Timber A DG Argon Fill Low Solar Gain low-E - Clear: U-value 2, SHGC 0.18
  • TIM-006-04 W Timber B DG Argon Fill Low Solar Gain low-E - Clear: U-value 2, SHGC 0.23

Window schedule

  • Gym/Vestibule/Store, window TIM-006-04 W: 2,800 × 3,800 mm facing NW
  • Gym/Vestibule/Store, window TIM-005-04 W: 2,400 × 900 mm facing NW
  • Gym/Vestibule/Store, window TIM-006-04 W: 2,800 × 1,370 mm facing W
  • Kitchen/Living, window TIM-006-04 W: 3,000 × 900 mm facing NW
  • Kitchen/Living, window TIM-006-04 W: 3,000 × 900 mm facing NW
  • Kitchen/Living, window TIM-006-04 W: 1,850 × 1,905 mm facing W
  • Kitchen/Living, window TIM-006-04 W: 1,850 × 1,905 mm facing NW
  • Kitchen/Living, window TIM-006-04 W: 1,850 × 1,905 mm facing N
  • Kitchen/Living, window TIM-005-04 W: 2,400 × 1,800 mm facing NE
  • Kitchen/Living, window TIM-006-04 W: 1,850 × 1,905 mm facing E
  • Kitchen/Living, window TIM-006-04 W: 1,850 × 1,905 mm facing SE
  • Kitchen/Living, window TIM-005-04 W: 2,400 × 1,100 mm facing NE
  • Kitchen/Living, window TIM-006-04 W: 2,400 × 3,308 mm facing SE
  • Kitchen/Living, window TIM-006-04 W: 1,350 × 619 mm facing SE
  • Kitchen/Living, window TIM-006-04 W: 1,350 × 4,785 mm facing SW
  • Entry/Hallway, window TIM-006-04 W: 1,950 × 1,430 mm facing NW
  • Entry/Hallway, window TIM-005-04 W: 2,745 × 1,700 mm facing NE
  • Entry/Hallway, window TIM-006-04 W: 1,500 × 650 mm facing NE
  • Entry/Hallway, window TIM-006-04 W: 2,400 × 750 mm facing SE
  • Entry/Hallway, window TIM-006-04 W: 2,400 × 750 mm facing SE
  • Entry/Hallway, window TIM-006-04 W: 2,400 × 1,500 mm facing SE
  • Entry/Hallway, window TIM-006-04 W: 1,500 × 3,220 mm facing SE
  • Entry/Hallway, window TIM-006-04 W: 2,400 × 750 mm facing SW
  • Entry/Hallway, window TIM-006-04 W: 2,400 × 750 mm facing SW
  • Entry/Hallway, window TIM-005-04 W: 2,400 × 1,500 mm facing SW
  • Entry/Hallway, window TIM-006-04 W: 2,400 × 750 mm facing SW
  • Entry/Hallway, window TIM-006-04 W: 2,400 × 750 mm facing SW
  • Entry/Hallway, window TIM-005-04 W: 2,400 × 1,500 mm facing SW
  • Entry/Hallway, window TIM-005-04 W: 2,400 × 1,500 mm facing SW
  • Formal Lounge, window TIM-006-04 W: 1,250 × 2,100 mm facing NE
  • Formal Lounge, window TIM-006-04 W: 1,250 × 1,700 mm facing NE
  • Formal Lounge, window TIM-005-04 W: 2,400 × 1,500 mm facing SE
  • Formal Lounge, window TIM-006-04 W: 1,500 × 1,433 mm facing NW
  • Formal Lounge, window TIM-006-04 W: 1,330 × 1,426 mm facing NW
  • Formal Lounge, window TIM-006-04 W: 1,330 × 1,426 mm facing NW
  • Formal Lounge, window TIM-006-04 W: 1,330 × 1,426 mm facing NW
  • Guest Bed 1, window TIM-006-04 W: 1,250 × 1,700 mm facing NE
  • Guest Bed 1, window TIM-006-04 W: 1,250 × 1,500 mm facing NE
  • Guest Bed 2, window TIM-006-04 W: 1,350 × 1,500 mm facing SW
  • Guest Bed 2, window TIM-006-04 W: 1,350 × 1,500 mm facing SW
  • Guest ENS 2, window TIM-006-04 W: 1,000 × 700 mm facing SW
  • Coffee Bar/Storage, window TIM-005-04 W: 1,500 × 2,524 mm facing SE
  • Coffee Bar/Storage, window TIM-006-04 W: 1,350 × 850 mm facing SW
  • Scullery/Cool room, window TIM-006-04 W: 1,350 × 4,170 mm facing SW
  • Scullery/Cool room, window TIM-006-04 W: 1,350 × 619 mm facing NW
  • Laundry, window TIM-005-04 W: 2,400 × 900 mm facing NW
  • Laundry, window TIM-006-04 W: 1,350 × 1,550 mm facing NW
  • Laundry, window TIM-006-04 W: 1,350 × 2,300 mm facing NE
  • Stair2 FF, window TIM-006-04 W: 1,350 × 3,000 mm facing NE
  • Void, window TIM-006-04 W: 1,705 × 900 mm facing NW
  • Void, window TIM-006-04 W: 1,705 × 900 mm facing NW
  • Void, window TIM-006-04 W: 800 × 1,800 mm facing W
  • Void, window TIM-006-04 W: 800 × 1,800 mm facing NW
  • Void, window TIM-006-04 W: 800 × 1,800 mm facing N
  • Void, window TIM-006-04 W: 800 × 1,800 mm facing NE
  • Void, window TIM-006-04 W: 800 × 1,800 mm facing E
  • Void, window TIM-006-04 W: 800 × 1,800 mm facing SE
  • Library, window TIM-005-04 W: 2,400 × 1,500 mm facing SW
  • Library, window TIM-006-04 W: 1,350 × 1,500 mm facing SE
  • Laundry FF, window TIM-006-04 W: 1,350 × 1,500 mm facing SW
  • Main Stair FF, window TIM-006-04 W: 1,950 × 1,890 mm facing W
  • Main Stair FF, window TIM-006-04 W: 1,950 × 2,520 mm facing NW
  • Main Stair FF, window TIM-006-04 W: 1,950 × 2,520 mm facing N
  • Main Stair FF, window TIM-006-04 W: 1,950 × 2,520 mm facing NE
  • Main Stair FF, window TIM-006-04 W: 1,950 × 1,890 mm facing E
  • Master Bed 1, window TIM-006-04 W: 1,350 × 5,220 mm facing NW
  • Master Bed 1, window TIM-006-04 W: 1,200 × 2,750 mm facing NW
  • Master Bed 1, window TIM-006-04 W: 2,820 × 1,550 mm facing NE
  • Bedroom 2, window TIM-006-04 W: 1,350 × 2,250 mm facing SE
  • Bedroom 3, window TIM-006-04 W: 1,350 × 750 mm facing SE
  • Bedroom 3, window TIM-006-04 W: 1,350 × 2,250 mm facing SW
  • Bedroom 4, window TIM-006-04 W: 1,350 × 2,250 mm facing SW
  • Bedroom 4, window TIM-006-04 W: 1,350 × 750 mm facing SE
  • Bedroom 5, window TIM-006-04 W: 1,350 × 2,250 mm facing SW
  • Bedroom 5, window TIM-006-04 W: 1,350 × 1,320 mm facing NW
  • Bedroom 5, window TIM-006-04 W: 1,350 × 1,500 mm facing NW
  • Study/Retreat, window TIM-006-04 W: 1,250 × 1,650 mm facing NE
  • Study/Retreat, window TIM-006-04 W: 1,250 × 700 mm facing NE
  • Study/Retreat, window TIM-006-04 W: 1,350 × 3,000 mm facing SE
  • Master1 ENS, window TIM-006-04 W: 2,625 × 2,250 mm facing SE
  • Master1 ENS, window TIM-006-04 W: 1,350 × 1,500 mm facing SW
  • WIR/ENS 2, window TIM-006-04 W: 1,350 × 750 mm facing SE
  • ENS 3, window TIM-006-04 W: 1,350 × 750 mm facing SE
  • ENS 5, window TIM-006-04 W: 1,350 × 750 mm facing SW
  • ENS 5, window TIM-006-04 W: 1,350 × 750 mm facing SW

Certificate 0009169129, issued 22 December 2023, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.