North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
6 Knox Place Normanhurst NSW 2076
Finding the block on the map…
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 2,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor.
Key features
- Windows
- 30 windows and glazed doors: Aluminium A SG Clear; Al Thermally Broken A DG Argon Fill High Solar Gain low-E - Clear; Al Thermally Broken B DG Argon Fill High Solar Gain low-E - Clear and 1 more types
- Wall insulation
- R2.5, R2
- Roof and ceiling insulation
- Ceiling R2.5, R5, R4, roof Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, dark colour
- Hot water
- Gas instantaneous with a performance of 5.5 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 72 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -79
- Heating load
- 13 MJ/m² a year
- Cooling load
- 17 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 249.1 m²
- Unconditioned floor area
- 10.7 m²
- Site area
- 465 m²
- Roof area
- 274 m²
- Garden area
- 100 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 5.5 stars
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 97.3 m², single glazing 3.4 m², double glazing 94.7 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
- Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (not specified)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - terracotta tiles , timber - untreated softwood (ceiling: fibreglass batts or roll; roof: none.)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1739738S_02, issued 13 March 2024, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.1.7 (3.22)
- Rated on
- 13 Mar 2024
- Wall insulation
- R2.5, R2
- Ceiling insulation
- R2.5, R5, R4
- Floor insulation
- R2.5, R2
- LED downlights
- 15
- Living room glazing by direction
- N 13.9 m², E 27.3 m², S 1 m²
- All glazing by direction
- N 21.2 m², E 49.3 m², S 9.2 m², W 20.4 m²
Roof
- Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, dark colour
- Corrugated Iron Timber Frame Bulk, Reflective Side Down, Anti-glare Up R1.3, medium colour
- Roof Tiles Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, dark colour
Window types
- ALM-001-01 A Aluminium A SG Clear: U-value 6.7, SHGC 0.57
- ATB-005-03 B Al Thermally Broken A DG Argon Fill High Solar Gain low-E - Clear: U-value 2.9, SHGC 0.44
- ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar Gain low-E - Clear: U-value 2.9, SHGC 0.51
- VEL-011-01 W VELUX FS - Fixed Skylight DG 3mm LoE 366 / 8.5mm Argon Gap / 5.36mm Clear La: U-value 2.6, SHGC 0.24
Window schedule
- Garage, window ALM-001-01 A: 2,800 × 1,200 mm facing S
- Guest Bed, window ATB-005-03 B: 2,200 × 1,000 mm facing W
- Guest Bed, window ATB-005-03 B: 2,200 × 1,000 mm facing W
- ENS Guest, window ATB-005-03 B: 700 × 1,350 mm facing N
- LDY GF, window ALM-001-01 A: 650 × 500 mm facing N
- LDY GF, window ALM-001-01 A: 2,400 × 820 mm facing N
- Pantry GF, window ATB-006-03 B: 650 × 1,700 mm facing S
- Kitchen/Living, window ATB-005-03 B: 2,500 × 800 mm facing N
- Kitchen/Living, window ATB-005-03 B: 2,500 × 800 mm facing N
- Kitchen/Living, window ATB-006-03 B: 3,000 × 5,400 mm facing E
- Kitchen/Living, window ATB-006-03 B: 3,000 × 3,700 mm facing E
- Kitchen/Living, window ATB-005-03 B: 650 × 800 mm facing S
- Kitchen/Living, window ATB-005-03 B: 650 × 800 mm facing S
- Bedroom 1 FF, window ATB-005-03 B: 2,000 × 1,000 mm facing W
- Bedroom 1 FF, window ATB-005-03 B: 2,000 × 1,000 mm facing W
- ENS 1 FF, window ATB-005-03 B: 700 × 1,350 mm facing N
- Master Bed FF, window ATB-005-03 B: 2,500 × 500 mm facing S
- Master Bed FF, window ATB-005-03 B: 2,500 × 500 mm facing S
- Master Bed FF, window ATB-005-03 B: 2,000 × 1,000 mm facing W
- Master Bed FF, window ATB-005-03 B: 2,000 × 1,000 mm facing W
- Master Bed FF, window ATB-005-03 B: 2,000 × 1,000 mm facing W
- ENS Mas FF, window ATB-005-03 B: 700 × 1,700 mm facing S
- Bedroom 3 FF, window ATB-006-03 B: 2,600 × 2,500 mm facing E
- Bedroom 2 FF, window ATB-006-03 B: 2,600 × 2,650 mm facing E
- Bedroom 2 FF, window ATB-005-03 B: 2,500 × 850 mm facing N
- Bedroom 2 FF, window ATB-005-03 B: 2,500 × 1,000 mm facing W
- Bath FF, window ATB-005-03 B: 700 × 1,350 mm facing N
- Void 1, window ATB-006-03 B: 2,000 × 1,750 mm facing W
- Void 2 FF, window ATB-006-03 B: 2,600 × 3,300 mm facing E
- Formal Liv GF, window ATB-006-03 B: 3,000 × 3,300 mm facing N
Certificate 0009303488, issued 13 March 2024, from the council's DA documents. Verify this certificate