52A Albert Road Beecroft NSW 2119

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 4,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 73 against 72.

Key features

Windows
33 windows and glazed doors: Aluminium A DG Air Fill High Solar Gain low-E - Clear; Aluminium B DG Air Fill High Solar Gain low-E - Clear; Al Thermally Broken A DG Air Fill Low Solar Gain low-E -Clear and 1 more types
Wall insulation
R1.0, R2.7
Roof and ceiling insulation
Ceiling R2.5, R4.0, roof Tiles (concrete) - DARK, dark colour
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Rcc National.

BASIX certificate

Energy score
73 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
15 MJ/m² a year
Cooling load
15 MJ/m² a year
Bedrooms
4
Conditioned floor area
191.9 m²
Unconditioned floor area
36.2 m²
Site area
1,429 m²
Roof area
264 m²
Garden area
802 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Rainwater tank
4,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 75.5 m², double glazing 75.5 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, hard wood; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • Floor: above habitable rooms or mezzanine, hard wood; frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, hard wood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: no frame (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: cavity brick; frame: no frame (fibreglass batts or roll)
  • Internal wall shared with garage: single skin masonry; frame: no frame (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - terracotta tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1791577S_02, issued 31 July 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
AccuRate Home v1.3.3.23
Rated on
11 Apr 2025
Wall insulation
R1.0, R2.7
Ceiling insulation
R2.5, R4.0
Floor insulation
R1.0, R2.7, R2.5, R4.0
Living room glazing by direction
N 5.6 m², S 10.5 m²
All glazing by direction
N 19.1 m², E 18.7 m², S 26.3 m², W 11.4 m²

Roof

  • Tiles (concrete) - DARK, dark colour
  • Timber balcony frame + tiles, medium colour
  • Flat roof anticon + R4.0 - DARK R5.2, dark colour

Window types

  • ALM-003-03 A Aluminium A DG Air Fill High Solar Gain low-E - Clear: U-value 4.3, SHGC 0.47
  • ALM-004-03 A Aluminium B DG Air Fill High Solar Gain low-E - Clear: U-value 4.3, SHGC 0.53
  • ATB-003-04 B Al Thermally Broken A DG Air Fill Low Solar Gain low-E -Clear: U-value 3.1, SHGC 0.27
  • ATB-004-04 B Al Thermally Broken B DG Air Fill Low Solar Gain low-E -Clear: U-value 3.1, SHGC 0.27

Window schedule

  • garage, window ALM-004-03 A: 857 × 1,450 mm facing W
  • store 2, window ALM-004-03 A: 1,200 × 1,690 mm facing S
  • store 2, window ALM-004-03 A: 1,200 × 1,210 mm facing E
  • wc, window ALM-004-03 A: 857 × 490 mm facing S
  • store 3, window ALM-004-03 A: 1,200 × 970 mm facing S
  • bed 1, window ALM-004-03 A: 1,372 × 1,450 mm facing W
  • bed 1, window ALM-004-03 A: 1,372 × 4,690 mm facing S
  • bed 1, window ALM-004-03 A: 2,173 × 1,810 mm facing E
  • kitchen/dining, window ALM-004-03 A: 2,173 × 2,490 mm facing S
  • living/lounge, window ALM-003-03 A: 1,629 × 850 mm facing S
  • living/lounge, window ALM-003-03 A: 2,173 × 1,690 mm facing S
  • living/lounge, window ALM-004-03 A: 1,200 × 1,570 mm facing N
  • living/lounge, window ALM-003-03 A: 2,173 × 1,690 mm facing N
  • bed 2, window ALM-004-03 A: 1,372 × 1,690 mm facing S
  • bed 2, window ALM-004-03 A: 1,372 × 1,210 mm facing E
  • bed 4, window ALM-004-03 A: 1,372 × 2,530 mm facing S
  • bed 4, window ALM-004-03 A: 1,372 × 1,210 mm facing E
  • bed 4, window ALM-004-03 A: 1,372 × 1,210 mm facing E
  • bed 4, window ALM-004-03 A: 1,372 × 2,530 mm facing N
  • bed 3, window ALM-004-03 A: 1,372 × 1,690 mm facing N
  • bath, window ALM-004-03 A: 943 × 970 mm facing N
  • sunroom, window ATB-004-04 B: 1,600 × 1,150 mm facing E
  • sunroom, window ATB-004-04 B: 2,150 × 2,150 mm facing E
  • sunroom, window ATB-004-04 B: 1,600 × 1,150 mm facing E
  • sunroom, window ATB-004-04 B: 1,600 × 1,150 mm facing N
  • sunroom, window ATB-004-04 B: 1,600 × 1,150 mm facing N
  • sunroom, window ATB-004-04 B: 1,600 × 1,150 mm facing N
  • sunroom, window ATB-004-04 B: 1,600 × 1,150 mm facing W
  • sunroom, window ATB-004-04 B: 1,600 × 1,150 mm facing W
  • sunroom, window ATB-004-04 B: 1,600 × 1,150 mm facing W
  • sunroom, window ATB-003-04 B: 2,150 × 900 mm facing W
  • laundry, window ALM-004-03 A: 1,200 × 1,090 mm facing N
  • ensuite, window ALM-004-03 A: 857 × 850 mm facing W

Certificate 0011857406, issued 11 April 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1791577S, issued 11 April 2025

BASIX certificate

Energy score
74 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
15 MJ/m² a year
Cooling load
15 MJ/m² a year
Bedrooms
4
Conditioned floor area
191.9 m²
Unconditioned floor area
36.2 m²
Site area
1,429 m²
Roof area
264 m²
Garden area
802 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Rainwater tank
4,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 75.5 m², double glazing 75.5 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, hard wood; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • Floor: above habitable rooms or mezzanine, hard wood; frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, hard wood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: no frame (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: cavity brick; frame: no frame (fibreglass batts or roll)
  • Internal wall shared with garage: single skin masonry; frame: no frame (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - terracotta tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)