5 Marine Crescent Hornsby Heights NSW 2077
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 0.1 kW of solar panels and a 1,400 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor.
Key features
- Windows
- 3 windows and glazed doors: Aluminium B SG Clear
- Wall insulation
- R2.0
- Roof and ceiling insulation
- Ceiling R4.0, roof Cont:Attic-Continuous 0.0, medium colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, non ducted (living area)
BASIX certificate
- Energy score
- 68 (target 68)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -55
- Heating load
- 14 MJ/m² a year
- Cooling load
- 16 MJ/m² a year
- Bedrooms
- 1
- Conditioned floor area
- 23.5 m²
- Unconditioned floor area
- 4.8 m²
- Site area
- 784 m²
- Roof area
- 45 m²
- Garden area
- 50 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 0.1 kW
- Rainwater tank
- 1,400 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 7.8 m², single glazing 7.8 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: 6 star (average zone)
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: 6 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: cavity brick; frame: timber - untreated softwood. all external walls polystyrene
- External garage wall: cavity brick; frame: timber - untreated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1793160S_03, issued 4 July 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 28 Apr 2025
- Wall insulation
- R2.0
- Ceiling insulation
- R4.0
- Floor insulation
- R2.0
- Living room glazing by direction
- NE 2.6 m², NW 3.8 m²
- All glazing by direction
- NE 2.6 m², NW 5.1 m²
Roof
- Cont:Attic-Continuous 0.0, medium colour
Window types
- ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7
Window schedule
- BED, window ALM-002-01 A: 1,400 × 915 mm facing NW
- LIV/KIT, window ALM-002-01 A: 1,100 × 2,400 mm facing NE
- LIV/KIT, window ALM-002-01 A: 2,400 × 1,595 mm facing NW
Certificate HM5UV46DRW, issued 28 April 2025, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate (alterations and additions), certificate A1793149_02, issued 4 July 2025
BASIX certificate (alterations and additions)
This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.
- LED lighting
- Yes
Construction and insulation
- Concrete slab on ground floor (no added insulation)
- Floor above existing dwelling or building (no added insulation)
- External wall: brick veneer R1.16 (or R1.70 including construction)
- External wall: framed (weatherboard, fibro, metal clad) R1.30 (or R1.70 including construction)
- Flat ceiling, flat roof: framed ceiling: R2.50 (up), roof: foil/sarking dark (solar absorptance > 0.70)
Certificate A1793149_02, issued 4 July 2025, from the council's DA documents.
BASIX certificate (alterations and additions), certificate A1793149, issued 28 April 2025
BASIX certificate (alterations and additions)
This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.
- LED lighting
- Yes
Construction and insulation
- Concrete slab on ground floor (no added insulation)
- Floor above existing dwelling or building (no added insulation)
- External wall: brick veneer R1.16 (or R1.70 including construction)
- External wall: framed (weatherboard, fibro, metal clad) R1.30 (or R1.70 including construction)
- Flat ceiling, flat roof: framed ceiling: R2.50 (up), roof: foil/sarking dark (solar absorptance > 0.70)
Certificate A1793149, issued 28 April 2025, from the council's DA documents.
BASIX certificate, certificate 1793160S, issued 28 April 2025
BASIX certificate
- Energy score
- 69 (target 68)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -55
- Heating load
- 14 MJ/m² a year
- Cooling load
- 16 MJ/m² a year
- Bedrooms
- 1
- Conditioned floor area
- 23.5 m²
- Unconditioned floor area
- 4.8 m²
- Site area
- 784 m²
- Roof area
- 45 m²
- Garden area
- 50 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 0.1 kW
- Rainwater tank
- 1,400 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 7.8 m², single glazing 7.8 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: 6 star (average zone)
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: 6 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: cavity brick; frame: timber - untreated softwood. all external walls polystyrene
- External garage wall: cavity brick; frame: timber - untreated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1793160S, issued 28 April 2025, from the council's DA documents.