BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 4.15 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy target, scoring 100 against 72.
Key features
- Windows
- Up to aluminium frames 77.3 m², single glazing 1.9 m², double glazing 75.4 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 100 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -47
- Heating load
- 13 MJ/m² a year
- Cooling load
- 16 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 238.5 m²
- Unconditioned floor area
- 17.2 m²
- Site area
- 696 m²
- Roof area
- 261 m²
- Garden area
- 313 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Solar panels
- 4.15 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 77.3 m², single glazing 1.9 m², double glazing 75.4 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: suspended floor above enclosed subfloor, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above open subfloor, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: AAC structural panel (150-200 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1815976S_03, issued 24 March 2026, from the council's DA documents.