Skip to main content

23 Pulbrook Parade Hornsby NSW 2077

Finding the block on the map…

BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to 0.6 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy target, scoring 69 against 68.

Key features

Windows
Up to uPVC frames 8.7 m², timber frames 0.4 m², single glazing 0.4 m², double glazing 8.7 m²
Wall insulation
Rockwool batts, roll or pump-in+ foil/sarking; Polystyrene
Roof and ceiling insulation
Ceiling: rockwool batts, roll or pump-in; roof: foil/sarking
Hot water
Electric storage
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
69 (target 68)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
17
Heating load
15 MJ/m² a year
Cooling load
12 MJ/m² a year
Bedrooms
2
Conditioned floor area
58.9 m²
Site area
784 m²
Roof area
30 m²
Garden area
196 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric storage
Solar panels
0.6 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 6 star, kitchen taps 6 star, basin taps 6 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
uPVC frames 8.7 m², timber frames 0.4 m², single glazing 0.4 m², double glazing 8.7 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: above habitable rooms or mezzanine, plywood; frame: laminated veneer lumber (LVL) (no added insulation)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (rockwool batts, roll or pump-in+ foil/sarking)
  • External wall: concrete block/plasterboard; frame: timber - H2 treated softwood (polystyrene)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil/sarking.)

Certificate 1755668S, issued 14 July 2024, from the council's DA documents.

Other certificates for this address

BASIX certificate (alterations and additions), certificate A1755667, issued 14 July 2024

BASIX certificate (alterations and additions)

This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.

LED lighting
Yes

Construction and insulation

  • Concrete slab on ground floor (no added insulation)
  • Suspended floor with enclosed subfloor: framed (R0.7). R0.60 (down) (or R1.30 including construction) N/A
  • External wall: framed (weatherboard, fibro, metal clad) R1.30 (or R1.70 including construction)
  • External wall: concrete block/ plasterboard R1.18 (or R1.70 including construction)
  • Internal wall shared with garage: plasterboard (R0.36)
  • Flat ceiling, pitched roof ceiling: R3.00 (up), roof: foil/sarking dark (solar absorptance > 0.70)

Certificate A1755667, issued 14 July 2024, from the council's DA documents.