Skip to main content

22 Marguerite Crescent West Pennant Hills NSW 2125

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 6.6 kW of solar panels and a 4,990 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 100 against 72.

Key features

Windows
17 windows and glazed doors: Timber A SG Clear; Timber B SG Clear; 5020 Comet Awning DG 6mmClr_12Ar_4mmClr and 2 more types
Wall insulation
R2.2
Roof and ceiling insulation
Ceiling R6.0, R4.1, roof Cont:Attic-Continuous 1.8, dark colour
Hot water
Electric heat pump
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

Built by McDonald Jones Homes.

BASIX certificate

Energy score
100 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-88
Heating load
19 MJ/m² a year
Cooling load
11 MJ/m² a year
Bedrooms
6
Conditioned floor area
205.4 m²
Unconditioned floor area
30.5 m²
Site area
790 m²
Roof area
272 m²
Garden area
350 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric heat pump
Solar panels
6.6 kW
Rainwater tank
4,990 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 40 m², timber frames 3.5 m², single glazing 3.5 m², double glazing 40 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: suspended floor above open subfloor, particle board; frame: light steel frame (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, particle board; frame: light steel frame (fibreglass batts or roll)
  • Floor: suspended floor above garage, particle board; frame: light steel frame (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: light steel frame (fibreglass batts or roll)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: light steel frame (fibreglass batts or roll)
  • External garage wall: AAC veneer; frame: light steel frame (no added insulation)
  • Internal wall: plasterboard; frame: light steel frame (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1792855S_02, issued 21 June 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
24 Apr 2025
Wall insulation
R2.2
Ceiling insulation
R6.0, R4.1
Floor insulation
R2.2, R4.1
Living room glazing by direction
NE 11.3 m²
All glazing by direction
NE 18.6 m², SE 3.3 m², SW 12.7 m², NW 9 m²

Roof

  • Cont:Attic-Continuous 1.8, dark colour

Window types

  • TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
  • TIM-002-01 W Timber B SG Clear: U-value 5.4, SHGC 0.63
  • CPT-006-31 A 5020 Comet Awning DG 6mmClr_12Ar_4mmClr: U-value 3.96, SHGC 0.54
  • TND-034-01 A Trend SoundMizer Al Sliding Window SEC 70mm 3/70/5: U-value 3.12, SHGC 0.61
  • WID-033-05 A BSSD Ascend Sliding Stacker Door DG 5mmClr_6Ar_5mmClr: U-value 4.03, SHGC 0.58

Window schedule

  • Guest Bedroom, window CPT-006-31 A: 1,543 × 3,010 mm facing SW
  • Activities, window TND-034-01 A: 1,030 × 2,650 mm facing NE
  • Guest Bed, window TND-034-01 A: 1,030 × 2,410 mm facing NE
  • Entry, window TIM-001-01 W: 2,106 × 1,200 mm facing SW
  • Entry, window TIM-002-01 W: 2,106 × 475 mm facing SW
  • Laundry, window WID-033-05 A: 2,100 × 1,570 mm facing SE
  • Kitchen/Family/-Dining, window WID-033-05 A: 2,100 × 5,364 mm facing NE
  • Ensuite 2, window TND-034-01 A: 400 × 1,210 mm facing NW
  • Garage, window WID-033-05 A: 2,100 × 1,450 mm facing NW
  • Master Suite, window CPT-006-31 A: 1,770 × 850 mm facing SW
  • Master Suite, window CPT-006-31 A: 1,770 × 850 mm facing SW
  • Bedroom 2, window CPT-006-31 A: 1,200 × 1,810 mm facing NW
  • Bedroom 3, window CPT-006-31 A: 1,200 × 1,810 mm facing NW
  • Bedroom 4, window CPT-006-31 A: 587 × 2,650 mm facing NE
  • Bathroom, window CPT-006-31 A: 857 × 610 mm facing NE
  • Ensuite, window CPT-006-31 A: 1,800 × 610 mm facing NW
  • Ensuite, window CPT-006-31 A: 1,770 × 850 mm facing SW

Certificate 0WAPF5ITZK, issued 24 April 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1792855S, issued 24 April 2025

BASIX certificate

Energy score
91 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-88
Heating load
19 MJ/m² a year
Cooling load
11 MJ/m² a year
Bedrooms
6
Conditioned floor area
205.4 m²
Unconditioned floor area
30.5 m²
Site area
790 m²
Roof area
272 m²
Garden area
350 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
6.6 kW
Rainwater tank
4,990 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 40 m², timber frames 3.5 m², single glazing 3.5 m², double glazing 40 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: suspended floor above open subfloor, particle board; frame: light steel frame (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, particle board; frame: light steel frame (fibreglass batts or roll)
  • Floor: suspended floor above garage, particle board; frame: light steel frame (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: light steel frame (fibreglass batts or roll)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: light steel frame (fibreglass batts or roll)
  • External garage wall: AAC veneer; frame: light steel frame (no added insulation)
  • Internal wall: plasterboard; frame: light steel frame (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1792855S, issued 24 April 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.