Skip to main content

14 Bryan Avenue Normanhurst NSW 2076

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 1.5 kW of solar panels and a 5,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 42 against 40.

Key features

Windows
49 windows and glazed doors: Timber B DG Argon Fill High Solar Gain low-E -Clear; IDEAL 2000 Inward Opening Door DG LightBridge_ClrSO_5-14-5; 60mm Sliding Window DG LightBridge_ClrSO_5-14-5 and 4 more types
Wall insulation
R2.7, R3.5
Roof and ceiling insulation
Ceiling R6.0, R2.5, R3.0, roof Framed:Flat - Flat Framed (Metal Deck) 0.0, dark colour
Hot water
Gas instantaneous with a performance of 4 stars
Air conditioning and heating
Airconditioning ducting only (living area and bedroom); Electric resistance space heating (living area)

BASIX certificate

Energy score
72 (target 72)
Water score
42 (target 40)
Thermal performance
Pass
Materials score
-22
Heating load
14 MJ/m² a year
Cooling load
15 MJ/m² a year
Bedrooms
4
Conditioned floor area
359 m²
Unconditioned floor area
20 m²
Site area
725 m²
Roof area
420 m²
Garden area
258 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 4 stars
Solar panels
1.5 kW
Rainwater tank
5,000 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Electric
Clothes line
Yes
Maximum glazing
aluminium frames 65 m², timber frames 15 m², single glazing 4.5 m², double glazing 75.5 m²

Heating

  • Living area: electric resistance space heating; Energy rating: n/a
  • Bedroom: airconditioning ducting only; Energy rating: n/a

Cooling

  • Living area: airconditioning ducting only; Energy rating: n/a
  • Bedroom: airconditioning ducting only; Energy rating: n/a

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: above habitable rooms or mezzanine, hard wood; frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, hard wood; frame: timber - H2 treated softwood (no added insulation)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1812551S_02, issued 20 November 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
11 Sep 2025
Wall insulation
R2.7, R3.5
Ceiling insulation
R6.0, R2.5, R3.0
Floor insulation
R2.7, R3.5, R2, R2.5, R1.5
Living room glazing by direction
E 46.2 m², W 3.6 m²
All glazing by direction
N 19.9 m², E 55.1 m², S 8 m², W 18.6 m²

Roof

  • Framed:Flat - Flat Framed (Metal Deck) 0.0, dark colour
  • Cont:Attic-Continuous 0.0, dark colour

Window types

  • TIM-006-03 W Timber B DG Argon Fill High Solar Gain low-E -Clear: U-value 2, SHGC 0.31
  • ALU-016-04 W IDEAL 2000 Inward Opening Door DG LightBridge_ClrSO_5-14-5: U-value 1.57, SHGC 0.35
  • ALU-004-10 W 60mm Sliding Window DG LightBridge_ClrSO_5-14-5: U-value 2.08, SHGC 0.36
  • ALU-014-05 W IDEAL 2000 Tilt n Turn Window DG LightBridge_ClrSO_4-16-4: U-value 1.56, SHGC 0.43
  • BRZ-003-13 A 52mm Altair Louvre Window System SG 6LE: U-value 4.3, SHGC 0.57
  • ALU-018-04 W IDEAL 4000 Fixed Window DG LightBridge_ClrSO_5-14-5: U-value 1.49, SHGC 0.39
  • ALU-010-04 W IDEAL 2000 Awning Window DG LightBridge_ClrSO_5-14-5: U-value 1.58, SHGC 0.32

Window schedule

  • Rumpus, window ALU-016-04 W: 2,400 × 4,000 mm facing E
  • Rumpus, window ALU-016-04 W: 2,400 × 3,965 mm facing E
  • Pantry, window ALU-004-10 W: 1,400 × 1,600 mm facing S
  • Sun Room, window ALU-004-10 W: 1,600 × 1,000 mm facing N
  • Sun Room, window ALU-004-10 W: 1,600 × 1,000 mm facing N
  • Sun Room, window ALU-004-10 W: 1,800 × 2,293 mm facing W
  • Entry, window TIM-006-03 W: 2,850 × 450 mm facing W
  • Entry, window TIM-006-03 W: 2,850 × 450 mm facing W
  • Entry, window TIM-006-03 W: 450 × 1,282 mm facing W
  • Kitchen/Living/-Dining, window ALU-014-05 W: 2,400 × 3,500 mm facing E
  • Kitchen/Living/-Dining, window BRZ-003-13 A: 2,400 × 900 mm facing E
  • Kitchen/Living/-Dining, window BRZ-003-13 A: 2,400 × 900 mm facing E
  • Kitchen/Living/-Dining, window ALU-014-05 W: 2,400 × 3,900 mm facing E
  • Bath, window ALU-004-10 W: 1,600 × 700 mm facing N
  • Laundry, window ALU-016-04 W: 2,100 × 913 mm facing N
  • Laundry, window ALU-018-04 W: 300 × 913 mm facing N
  • Ensuite, window ALU-010-04 W: 600 × 2,400 mm facing S
  • Bath, window ALU-004-10 W: 1,400 × 1,600 mm facing N
  • Bedroom 2, window ALU-010-04 W: 600 × 785 mm facing S
  • Bedroom 2, window ALU-010-04 W: 600 × 785 mm facing S
  • Bedroom 2, window ALU-018-04 W: 600 × 830 mm facing S
  • Bedroom 2, window ALU-004-10 W: 1,500 × 2,100 mm facing W
  • Master Bedroom, window ALU-010-04 W: 600 × 837 mm facing S
  • Master Bedroom, window ALU-018-04 W: 600 × 897 mm facing S
  • Master Bedroom, window ALU-010-04 W: 600 × 837 mm facing S
  • Master Bedroom, window ALU-004-10 W: 1,550 × 2,040 mm facing E
  • Bedroom 1, window ALU-010-04 W: 600 × 638 mm facing N
  • Bedroom 1, window ALU-010-04 W: 600 × 638 mm facing N
  • Bedroom 1, window ALU-018-04 W: 600 × 683 mm facing N
  • Bedroom 3, window ALU-010-04 W: 600 × 785 mm facing N
  • Bedroom 3, window ALU-010-04 W: 600 × 785 mm facing N
  • Bedroom 3, window ALU-018-04 W: 600 × 830 mm facing N
  • Bedroom 3, window ALU-004-10 W: 1,500 × 2,100 mm facing W
  • Void, window TIM-006-03 W: 1,200 × 1,200 mm facing E
  • Void, window TIM-006-03 W: 1,200 × 1,200 mm facing E
  • Void, window TIM-006-03 W: 1,200 × 1,200 mm facing E
  • Void, window TIM-006-03 W: 1,200 × 1,200 mm facing N
  • Void, window TIM-006-03 W: 1,200 × 1,200 mm facing N
  • Void, window TIM-006-03 W: 1,200 × 1,200 mm facing N
  • Void, window TIM-006-03 W: 1,200 × 1,200 mm facing N
  • Void, window TIM-006-03 W: 1,200 × 1,200 mm facing N
  • Lounge, window ALU-016-04 W: 2,100 × 1,200 mm facing E
  • Lounge, window ALU-018-04 W: 2,100 × 600 mm facing E
  • Lounge, window ALU-018-04 W: 2,100 × 600 mm facing E
  • Lounge, window TIM-006-03 W: 1,100 × 3,300 mm facing W
  • Void, window TIM-006-03 W: 900 × 1,500 mm facing W
  • Void, window TIM-006-03 W: 900 × 1,500 mm facing S
  • Void, window TIM-006-03 W: 900 × 1,500 mm facing E
  • Void, window TIM-006-03 W: 900 × 1,500 mm facing N

Certificate FLTHXQ2G6R, issued 11 September 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1812551S, issued 11 September 2025

BASIX certificate

Energy score
72 (target 72)
Water score
42 (target 40)
Thermal performance
Pass
Materials score
-22
Heating load
14 MJ/m² a year
Cooling load
15 MJ/m² a year
Bedrooms
4
Conditioned floor area
359 m²
Unconditioned floor area
20 m²
Site area
725 m²
Roof area
420 m²
Garden area
258 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 4 stars
Solar panels
1 kW
Rainwater tank
5,000 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 65 m², timber frames 15 m², single glazing 4.5 m², double glazing 75.5 m²

Heating

  • Living area: gas fixed flued heater - non ducted; Energy rating: 3 Star
  • Bedroom: airconditioning ducting only; Energy rating: n/a

Cooling

  • Living area: airconditioning ducting only; Energy rating: n/a
  • Bedroom: airconditioning ducting only; Energy rating: n/a

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: above habitable rooms or mezzanine, hard wood; frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, hard wood; frame: timber - H2 treated softwood (no added insulation)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1812551S, issued 11 September 2025, from the council's DA documents.

BASIX certificate, certificate 1736735S, issued 21 February 2024

BASIX certificate

Energy score
72 (target 72)
Water score
49 (target 40)
Thermal performance
Pass
Materials score
-26
Heating load
18 MJ/m² a year
Cooling load
12 MJ/m² a year
Bedrooms
4
Conditioned floor area
364 m²
Unconditioned floor area
20 m²
Site area
725 m²
Roof area
420 m²
Garden area
217 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 4 stars
Solar panels
1 kW
Rainwater tank
5,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 80.5 m², single glazing 80.5 m²

Heating

  • Living area: gas fixed flued heater - non ducted; Energy rating: 3 Star
  • Bedroom: airconditioning ducting only; Energy rating: n/a

Cooling

  • Living area: airconditioning ducting only; Energy rating: n/a
  • Bedroom: airconditioning ducting only; Energy rating: n/a

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: suspended floor above enclosed subfloor, hard wood; frame: timber - untreated softwood (not specified)
  • Floor: above habitable rooms or mezzanine, hard wood; frame: timber - untreated softwood (no added insulation)
  • Floor: suspended floor above garage, hard wood; frame: timber - untreated softwood (no added insulation)
  • Garage floor: concrete slab on ground (not specified)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1736735S, issued 21 February 2024, from the council's DA documents.