1 Wayfield Road Dural NSW 2158
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 5.7 kW of solar panels and a 5,000 litre rainwater tank.
Key features
- Windows
- 117 windows and glazed doors: Aluminium A SG Clear; Aluminium B SG Clear; Aluminium A DG Air Fill High Solar Gain low-E -Clear and 1 more types
- Wall insulation
- Polyurethane+ foil/sarking; Fibreglass batts or roll
- Roof and ceiling insulation
- Roof Added insulation absorptance Roof Colour SLAB-100-CEIL-01: Concrete Slab (100mm) with Suspended PB Ceiling 4.10, medium colour
- Hot water
- Gas boosted solar with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 38 MJ/m² a year
- Cooling load
- 22 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 1,413 m²
- Unconditioned floor area
- 27 m²
- Site area
- 17,770 m²
- Roof area
- 900 m²
- Garden area
- 983 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas boosted solar with a performance of 26 to 30 STCs or better
- Solar panels
- 5.7 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 491 m², single glazing 5 m², double glazing 486 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (polystyrene)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
- Floor: suspended floor above garage, concrete - suspended; frame: no frame (polystyrene)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: cavity brick; frame: no frame (polyurethane+ foil/sarking)
- External wall: framed (metal clad); frame: light steel frame (fibreglass batts or roll)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, no frame (ceiling: polystyrene; roof: none.)
Certificate 1814184S_03, issued 10 February 2026, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- Hero 4.1
- Rated on
- 13 Oct 2025
- Living room glazing by direction
- NE 76 m², SE 19.6 m², SW 12.6 m², NW 21.7 m²
- All glazing by direction
- NE 287.1 m², SE 61.5 m², SSE 5.8 m², SW 72.5 m², WNW 5.8 m², NW 58.6 m²
Roof
- Added insulation absorptance Roof Colour SLAB-100-CEIL-01: Concrete Slab (100mm) with Suspended PB Ceiling 4.10, medium colour
Window types
- ALM-001-01 A Aluminium A SG Clear: U-value 6.7, SHGC 0.57
- ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7
- ALM-003-03 A Aluminium A DG Air Fill High Solar Gain low-E -Clear: U-value 4.3, SHGC 0.47
- ALM-004-03 A Aluminium B DG Air Fill High Solar Gain low-E -Clear: U-value 4.3, SHGC 0.53
Window schedule
- Bed 2, window ALM-004-03 A: 2,850 × 3,800 mm facing NE
- Bed 2, window ALM-003-03 A: 2,850 × 800 mm facing NE
- Bed 3, window ALM-004-03 A: 2,850 × 3,800 mm facing NE
- Bed 3, window ALM-003-03 A: 2,850 × 800 mm facing NE
- Bed 3, window ALM-003-03 A: 2,700 × 1,000 mm facing SE
- Bed 3, window ALM-004-03 A: 2,700 × 1,000 mm facing SE
- Bed 4, window ALM-003-03 A: 2,700 × 1,000 mm facing NW
- Bed 4, window ALM-004-03 A: 2,700 × 1,000 mm facing NW
- Bed 4, window ALM-004-03 A: 2,850 × 3,800 mm facing NE
- Bed 4, window ALM-003-03 A: 2,850 × 800 mm facing NE
- Bed 5, window ALM-004-03 A: 2,850 × 3,800 mm facing NE
- Bed 5, window ALM-003-03 A: 2,850 × 800 mm facing NE
- Bed 6, window ALM-004-03 A: 2,900 × 3,200 mm facing NE
- Bed 6, window ALM-003-03 A: 2,900 × 800 mm facing NE
- Bed 6, window ALM-003-03 A: 2,900 × 800 mm facing NE
- Bed 6, window ALM-003-03 A: 1,000 × 1,500 mm facing SE
- Cloak, window ALM-003-03 A: 2,900 × 800 mm facing SW
- Dining, window ALM-003-03 A: 2,900 × 2,700 mm facing SE
- Dining, window ALM-004-03 A: 2,900 × 3,200 mm facing NE
- Dining, window ALM-003-03 A: 2,900 × 800 mm facing NE
- Dining, window ALM-003-03 A: 2,900 × 800 mm facing NE
- ENS 6, window ALM-004-03 A: 2,900 × 900 mm facing SE
- ENS 6, window ALM-004-03 A: 1,000 × 500 mm facing SE
- ENS M, window ALM-003-03 A: 1,800 × 800 mm facing SW
- Family, window ALM-004-03 A: 2,900 × 3,200 mm facing NE
- Family, window ALM-003-03 A: 2,900 × 800 mm facing NE
- Family, window ALM-003-03 A: 2,900 × 800 mm facing NE
- Family, window ALM-003-03 A: 2,900 × 2,700 mm facing SE
- Family, window ALM-004-03 A: 2,900 × 3,200 mm facing NE
- Family, window ALM-003-03 A: 2,900 × 800 mm facing NE
- Family, window ALM-003-03 A: 2,900 × 800 mm facing NE
- Family, window ALM-004-03 A: 1,800 × 1,100 mm facing SE
- Family, window ALM-004-03 A: 1,800 × 1,100 mm facing SE
- Family Cinema, window ALM-003-03 A: 1,800 × 800 mm facing SW
- Formal Dining, window ALM-004-03 A: 2,900 × 2,000 mm facing SW
- Formal Dining, window ALM-003-03 A: 2,900 × 1,100 mm facing SW
- Formal Dining, window ALM-004-03 A: 1,000 × 900 mm facing NW
- Formal Dining, window ALM-003-03 A: 2,900 × 1,100 mm facing NW
- GF Hall, window ALM-003-03 A: 2,900 × 2,000 mm facing SSE
- GF Hall, window ALM-003-03 A: 2,900 × 2,000 mm facing WNW
- GF Hall, window ALM-004-03 A: 2,900 × 4,400 mm facing NE
- GF Hall, window ALM-003-03 A: 2,900 × 800 mm facing NE
- GF Hall, window ALM-003-03 A: 2,900 × 800 mm facing NE
- GF Hall, window ALM-004-03 A: 2,900 × 2,100 mm facing SW
- GF Store 1, window ALM-003-03 A: 2,900 × 800 mm facing SW
- GF Study 1, window ALM-004-03 A: 1,000 × 900 mm facing SE
- GF Study 1, window ALM-003-03 A: 2,900 × 1,100 mm facing SE
- GF Study 1, window ALM-004-03 A: 2,900 × 2,000 mm facing SW
- GF Study 1, window ALM-003-03 A: 2,900 × 1,100 mm facing SW
- GF Study 2, window ALM-004-03 A: 2,900 × 3,200 mm facing NE
- GF Study 2, window ALM-003-03 A: 2,900 × 800 mm facing NE
- GF Study 2, window ALM-003-03 A: 2,900 × 800 mm facing NE
- GF Study 2, window ALM-003-03 A: 2,900 × 2,700 mm facing NW
- Games, window ALM-004-03 A: 2,850 × 3,800 mm facing NE
- Games, window ALM-004-03 A: 2,850 × 3,800 mm facing NE
- Games, window ALM-003-03 A: 2,850 × 800 mm facing NE
- Games, window ALM-003-03 A: 2,850 × 800 mm facing NE
- Games, window ALM-004-03 A: 2,700 × 1,000 mm facing SE
- Games, window ALM-003-03 A: 2,700 × 1,000 mm facing SE
- Games, window ALM-004-03 A: 1,200 × 10,100 mm facing NE
- Games, window ALM-003-03 A: 2,700 × 1,100 mm facing SE
- Games, window ALM-004-03 A: 1,800 × 1,100 mm facing SE
- Garage, window ALM-002-01 A: 550 × 5,100 mm facing SE
- Gym, window ALM-003-03 A: 1,800 × 1,100 mm facing SE
- Gym, window ALM-004-03 A: 1,800 × 900 mm facing SE
- Gym, window ALM-003-03 A: 1,800 × 1,100 mm facing SW
- Gym, window ALM-003-03 A: 1,800 × 800 mm facing SW
- Gym, window ALM-004-03 A: 1,800 × 2,000 mm facing SW
- Kitchen/Living, window ALM-003-03 A: 2,900 × 2,700 mm facing NW
- Kitchen/Living, window ALM-004-03 A: 2,900 × 3,200 mm facing NE
- Kitchen/Living, window ALM-003-03 A: 2,900 × 800 mm facing NE
- Kitchen/Living, window ALM-003-03 A: 2,900 × 800 mm facing NE
- Kitchen/Living, window ALM-003-03 A: 1,000 × 2,200 mm facing NW
- Kitchen/Living, window ALM-004-03 A: 2,900 × 3,200 mm facing NE
- Kitchen/Living, window ALM-003-03 A: 2,900 × 800 mm facing NE
- Kitchen/Living, window ALM-003-03 A: 2,900 × 800 mm facing NE
- L1 Hall, window ALM-004-03 A: 2,700 × 6,100 mm facing NE
- L1 Hall, window ALM-004-03 A: 2,700 × 600 mm facing SW
- L1 Hall, window ALM-004-03 A: 2,700 × 3,731 mm facing SW
- L1 Hall, window ALM-004-03 A: 2,850 × 1,200 mm facing SE
- L1 Hall, window ALM-004-03 A: 2,850 × 1,200 mm facing NW
- L1 Hall, window ALM-004-03 A: 2,850 × 1,400 mm facing SW
- L1 Storage, window ALM-003-03 A: 1,800 × 1,100 mm facing SW
- L1 Storage, window ALM-004-03 A: 1,800 × 700 mm facing SW
- L1 Study, window ALM-003-03 A: 1,800 × 1,100 mm facing SE
- L1 Study, window ALM-004-03 A: 1,800 × 1,100 mm facing SE
- L1 Study, window ALM-004-03 A: 1,200 × 5,300 mm facing NE
- Ldry, window ALM-001-01 A: 2,900 × 800 mm facing NW
- Majlis/Drawing, window ALM-003-03 A: 1,800 × 1,100 mm facing NW
- Majlis/Drawing, window ALM-004-03 A: 1,800 × 1,100 mm facing NW
- Majlis/Drawing, window ALM-004-03 A: 2,900 × 3,200 mm facing NE
- Majlis/Drawing, window ALM-003-03 A: 2,900 × 800 mm facing NE
- Majlis/Drawing, window ALM-003-03 A: 2,900 × 800 mm facing NE
- Master, window ALM-004-03 A: 2,850 × 3,800 mm facing NE
- Master, window ALM-004-03 A: 2,850 × 3,800 mm facing NE
- Master, window ALM-003-03 A: 2,850 × 800 mm facing NE
- Master, window ALM-003-03 A: 2,850 × 800 mm facing NE
- Master, window ALM-004-03 A: 1,800 × 1,100 mm facing NW
- Master, window ALM-003-03 A: 2,700 × 1,100 mm facing NW
- Master, window ALM-004-03 A: 1,200 × 10,100 mm facing NE
- Master, window ALM-003-03 A: 2,700 × 1,000 mm facing NW
- Master, window ALM-004-03 A: 2,700 × 1,000 mm facing NW
- Music/Media, window ALM-003-03 A: 1,800 × 1,100 mm facing SW
- Music/Media, window ALM-003-03 A: 1,800 × 800 mm facing SW
- Music/Media, window ALM-004-03 A: 1,800 × 2,130 mm facing SW
- Music/Media, window ALM-003-03 A: 1,800 × 1,100 mm facing SE
- Music/Media, window ALM-004-03 A: 1,800 × 900 mm facing SE
- Rumpus, window ALM-004-03 A: 1,800 × 1,185 mm facing SW
- Rumpus, window ALM-003-03 A: 1,800 × 1,100 mm facing NW
- Rumpus, window ALM-004-03 A: 1,800 × 900 mm facing NW
- Rumpus, window ALM-003-03 A: 1,800 × 1,100 mm facing NW
- Rumpus, window ALM-004-03 A: 1,800 × 1,100 mm facing NW
- Rumpus, window ALM-004-03 A: 1,200 × 5,300 mm facing NE
- WIR M, window ALM-003-03 A: 1,800 × 1,100 mm facing SW
- WIR M, window ALM-004-03 A: 1,800 × 2,000 mm facing SW
- WIR M, window ALM-003-03 A: 1,800 × 1,100 mm facing NW
- WIR M, window ALM-004-03 A: 1,800 × 900 mm facing NW
Certificate HR-RTRB86-02, issued 13 October 2025, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1814184S_02, issued 14 October 2025
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 38 MJ/m² a year
- Cooling load
- 22 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 1,413 m²
- Unconditioned floor area
- 27 m²
- Site area
- 17,770 m²
- Roof area
- 900 m²
- Garden area
- 983 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas boosted solar with a performance of 26 to 30 STCs or better
- Solar panels
- 5.7 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 491 m², single glazing 5 m², double glazing 486 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (polystyrene)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
- Floor: suspended floor above garage, concrete - suspended; frame: no frame (polystyrene)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: cavity brick; frame: no frame (polyurethane+ foil/sarking)
- External wall: framed (metal clad); frame: light steel frame (fibreglass batts or roll)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, no frame (ceiling: polystyrene; roof: none.)
Certificate 1814184S_02, issued 14 October 2025, from the council's DA documents.