Skip to main content

9 Bragg Street Wongarbon NSW 2831

Finding the block on the map…

BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to 2 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy target, scoring 93 against 65.

Key features

Windows
Up to aluminium frames 11.3 m², single glazing 11.3 m²
Wall insulation
All external walls fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil/sarking
Hot water
Electric storage
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
93 (target 65)
Water score
30 (target 30)
Materials score
1
Heating load
15 MJ/m² a year
Cooling load
28 MJ/m² a year
Bedrooms
2
Conditioned floor area
52 m²
Unconditioned floor area
7 m²
Site area
2,005 m²
Roof area
89 m²
Garden area
102 m²
Climate zone
NatHERS climate zone 48
Hot water
Electric storage
Solar panels
2 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 11.3 m², single glazing 11.3 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1860413S, issued 11 August 2026, from the council's DA documents.

Other certificates for this address

BASIX certificate, certificate 1860410S, issued 11 August 2026

BASIX certificate

Energy score
69 (target 68)
Water score
31 (target 30)
Materials score
-36
Heating load
39 MJ/m² a year
Cooling load
26 MJ/m² a year
Bedrooms
4
Conditioned floor area
163 m²
Unconditioned floor area
19 m²
Site area
2,005 m²
Roof area
313 m²
Garden area
257 m²
Climate zone
NatHERS climate zone 48
Hot water
Electric heat pump
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 26.5 m², single glazing 26.5 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1860410S, issued 11 August 2026, from the council's DA documents.