North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
55 Sunningdale Close Dubbo NSW 2830
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 5,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 33 against 30.
Key features
- Windows
- 21 windows and glazed doors: Timber A SG Clear; Aluminium Sliding Door SG 6.38LoEClr; Aluminium Fixed Window SG 6.38LoEClr and 2 more types
- Wall insulation
- R2.7
- Roof and ceiling insulation
- Ceiling R6, R3.5, roof Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, light colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by Brett Harvey Constructions.
BASIX certificate
- Energy score
- 68 (target 68)
- Water score
- 33 (target 30)
- Thermal performance
- Pass
- Materials score
- -28
- Heating load
- 67 MJ/m² a year
- Cooling load
- 12 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 187.8 m²
- Unconditioned floor area
- 7.1 m²
- Site area
- 643 m²
- Roof area
- 335 m²
- Garden area
- 189 m²
- Climate zone
- NatHERS climate zone 48
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 38.7 m², timber frames 0.7 m², single glazing 39.4 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (polystyrene)
- Garage floor: concrete slab on ground, waffle pod slab (polystyrene)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1823768S_02, issued 12 January 2026, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.2.6 (3.23)
- Rated on
- 26 Nov 2025
- Wall insulation
- R2.7
- Ceiling insulation
- R6, R3.5
- Floor insulation
- R2.7
- LED downlights
- 45
- Living room glazing by direction
- SE 8.1 m², SW 11.3 m²
- All glazing by direction
- NE 7.3 m², SE 9.9 m², SW 14.9 m², NW 7.3 m²
Roof
- Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, light colour
Window types
- TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
- BRD-033-022 Aluminium Sliding Door SG 6.38LoEClr: U-value 4, SHGC 0.6
- BRD-124-033 Aluminium Fixed Window SG 6.38LoEClr: U-value 3.8, SHGC 0.61
- BRD-024-028 Aluminium Double Hung Window SG 6.38LoEClr: U-value 4.3, SHGC 0.6
- BRD-001-031 Aluminium Sliding Window SG 6.38LoEClr: U-value 4.4, SHGC 0.61
Window schedule
- KIT/FAM/MEALS, window BRD-033-022: 2,100 × 4,200 mm facing SW
- KIT/FAM/MEALS, window BRD-124-033: 600 × 4,200 mm facing SW
- KIT/FAM/MEALS, window BRD-024-028: 2,000 × 900 mm facing SE
- KIT/FAM/MEALS, window BRD-024-028: 2,000 × 900 mm facing SE
- KIT/FAM/MEALS, window BRD-024-028: 2,000 × 900 mm facing SE
- PTY, window TIM-001-01 W: 1,050 × 820 mm facing NE
- PTY, window BRD-124-033: 600 × 1,500 mm facing SE
- LIVING, window BRD-024-028: 1,800 × 1,500 mm facing SE
- GARAGE, window BRD-001-031: 600 × 1,500 mm facing SE
- FOYER/HALL, window TIM-001-01 W: 1,800 × 1,200 mm facing NE
- REAR HALL, window BRD-124-033: 2,000 × 900 mm facing SW
- BED 2, window BRD-024-028: 2,000 × 900 mm facing SW
- BED 3, window BRD-024-028: 2,000 × 900 mm facing NW
- WC, window BRD-001-031: 900 × 900 mm facing NW
- BATH, window BRD-001-031: 1,200 × 1,500 mm facing NW
- BED 4, window BRD-001-031: 1,500 × 1,500 mm facing NW
- ES, window BRD-001-031: 400 × 1,500 mm facing NW
- BED 1, window BRD-024-028: 1,800 × 600 mm facing NE
- BED 1, window BRD-024-028: 1,800 × 600 mm facing NE
- BED 1, window BRD-024-028: 1,800 × 600 mm facing NE
- WIW, window BRD-024-028: 1,800 × 600 mm facing NE
Certificate 0012412433, issued 26 November 2025, from the council's DA documents. Verify this certificate