BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 37 against 30.

Key features

Windows
19 windows and glazed doors: Aluminium Double Hung Window SG 4EA; Aluminium Bifold Door SG 4EA; Aluminium Sliding Window SG 4EA and 1 more types
Wall insulation
R2.7
Roof and ceiling insulation
Ceiling R6, R3, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour
Hot water
Gas instantaneous with a performance of 5 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Brett Harvey Constructions.

BASIX certificate

Energy score
65 (target 65)
Water score
37 (target 30)
Thermal performance
Pass
Materials score
-9
Heating load
66 MJ/m² a year
Cooling load
13 MJ/m² a year
Bedrooms
3
Conditioned floor area
96.5 m²
Unconditioned floor area
12.8 m²
Site area
360 m²
Roof area
205 m²
Garden area
85 m²
Climate zone
NatHERS climate zone 48
Hot water
Gas instantaneous with a performance of 5 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 30.2 m², single glazing 30.2 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1802659S, issued 3 July 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
BERS Pro v5.2.4 (3.23)
Rated on
28 Mar 2025
Wall insulation
R2.7
Ceiling insulation
R6, R3
Floor insulation
R2.7
LED downlights
51
Living room glazing by direction
N 5.9 m², E 8.3 m², S 10.3 m², W 4.9 m²
All glazing by direction
N 5.9 m², E 18.2 m², S 11.7 m², W 18.3 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour

Window types

  • BRD-024-004 Aluminium Double Hung Window SG 4EA: U-value 4.4, SHGC 0.62
  • BRD-006-009 Aluminium Bifold Door SG 4EA: U-value 4.6, SHGC 0.52
  • BRD-001-013 Aluminium Sliding Window SG 4EA: U-value 4.6, SHGC 0.63
  • BRD-034-003 Aluminium Sliding Door SG 4EA: U-value 4.2, SHGC 0.63

Window schedule

  • KIT/FAM/MEALS, window BRD-024-004: 1,500 × 1,200 mm facing S
  • KIT/FAM/MEALS, window BRD-024-004: 1,500 × 1,200 mm facing S
  • KIT/FAM/MEALS, window BRD-024-004: 1,800 × 900 mm facing W
  • KIT/FAM/MEALS, window BRD-024-004: 1,800 × 900 mm facing W
  • KIT/FAM/MEALS, window BRD-006-009: 1,000 × 1,800 mm facing E
  • KIT/FAM/MEALS, window BRD-001-013: 1,500 × 1,800 mm facing E
  • KIT/FAM/MEALS, window BRD-034-003: 2,100 × 3,200 mm facing S
  • KIT/FAM/MEALS, window BRD-034-003: 2,100 × 1,800 mm facing E
  • BED 2, window BRD-001-013: 1,800 × 1,500 mm facing W
  • BED 3, window BRD-001-013: 1,800 × 1,500 mm facing W
  • LAUNDRY, window BRD-001-013: 900 × 1,500 mm facing S
  • BATH, window BRD-001-013: 2,100 × 1,500 mm facing W
  • WC, window BRD-001-013: 900 × 600 mm facing W
  • BED 4, window BRD-001-013: 1,800 × 2,400 mm facing W
  • ENS BATH, window BRD-001-013: 2,100 × 1,500 mm facing E
  • BED 1, window BRD-034-003: 2,100 × 3,200 mm facing E
  • LOUNGE/ENTRY, window BRD-024-004: 1,800 × 900 mm facing W
  • LOUNGE/ENTRY, window BRD-024-004: 1,800 × 900 mm facing N
  • LOUNGE/ENTRY, window BRD-001-013: 1,800 × 2,400 mm facing N

Certificate 0011814324, issued 28 March 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1802656S, issued 3 July 2025

BASIX certificate

Energy score
65 (target 65)
Water score
32 (target 30)
Thermal performance
Pass
Materials score
-52
Heating load
65 MJ/m² a year
Cooling load
13 MJ/m² a year
Bedrooms
4
Conditioned floor area
98 m²
Unconditioned floor area
11.3 m²
Site area
564 m²
Roof area
239 m²
Garden area
208 m²
Climate zone
NatHERS climate zone 48
Hot water
Gas instantaneous with a performance of 5 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 27.8 m², single glazing 27.8 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (no added insulation)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1802656S, issued 3 July 2025, from the council's DA documents.

BASIX certificate, certificate 1789424S, issued 28 March 2025

BASIX certificate

Energy score
68 (target 68)
Water score
30 (target 30)
Thermal performance
Pass
Materials score
-61
Heating load
52 MJ/m² a year
Cooling load
27 MJ/m² a year
Bedrooms
4
Conditioned floor area
217 m²
Unconditioned floor area
25.2 m²
Site area
1,085 m²
Roof area
388 m²
Garden area
415 m²
Climate zone
NatHERS climate zone 48
Hot water
Gas instantaneous with a performance of 5 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 54 m², single glazing 54 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1789424S, issued 28 March 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related