North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
411/-/DP1326380
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 3,000 litre rainwater tank. It beat its BASIX water target, scoring 31 against 30.
Key features
- Windows
- Up to aluminium frames 28.5 m², single glazing 28.5 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Gas instantaneous with a performance of 5 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 68 (target 68)
- Water score
- 31 (target 30)
- Materials score
- -58
- Heating load
- 60 MJ/m² a year
- Cooling load
- 19 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 118.7 m²
- Unconditioned floor area
- 13.8 m²
- Site area
- 492 m²
- Roof area
- 229 m²
- Garden area
- 158 m²
- Climate zone
- NatHERS climate zone 48
- Hot water
- Gas instantaneous with a performance of 5 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 28.5 m², single glazing 28.5 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: AAC veneer; frame: timber - H2 treated softwood (foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1854497S, issued 3 July 2026, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1854496S, issued 3 July 2026
BASIX certificate
- Energy score
- 66 (target 65)
- Water score
- 30 (target 30)
- Materials score
- -21
- Heating load
- 66 MJ/m² a year
- Cooling load
- 13 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 77.3 m²
- Unconditioned floor area
- 8.6 m²
- Site area
- 364 m²
- Roof area
- 153 m²
- Garden area
- 169 m²
- Climate zone
- NatHERS climate zone 48
- Hot water
- Gas instantaneous with a performance of 5 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 18.9 m², single glazing 18.9 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1854496S, issued 3 July 2026, from the council's DA documents.