North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
19 Violet Circuit Dubbo NSW 2830
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 3,000 litre rainwater tank.
Key features
- Windows
- Up to aluminium frames 18.7 m², single glazing 18.7 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Gas instantaneous with a performance of 5 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 65 (target 65)
- Water score
- 30 (target 30)
- Thermal performance
- Pass
- Materials score
- 3
- Heating load
- 61 MJ/m² a year
- Cooling load
- 15 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 78.3 m²
- Unconditioned floor area
- 9.4 m²
- Site area
- 582 m²
- Roof area
- 143 m²
- Garden area
- 182 m²
- Climate zone
- NatHERS climate zone 48
- Hot water
- Gas instantaneous with a performance of 5 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 18.7 m², single glazing 18.7 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1763959S, issued 11 September 2024, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1763957S, issued 11 September 2024
BASIX certificate
- Energy score
- 65 (target 65)
- Water score
- 30 (target 30)
- Thermal performance
- Pass
- Materials score
- -13
- Heating load
- 60 MJ/m² a year
- Cooling load
- 19 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 78.3 m²
- Unconditioned floor area
- 9.4 m²
- Site area
- 457 m²
- Roof area
- 143 m²
- Garden area
- 212 m²
- Climate zone
- NatHERS climate zone 48
- Hot water
- Gas instantaneous with a performance of 5 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 19.3 m², single glazing 19.3 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (not specified)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1763957S, issued 11 September 2024, from the council's DA documents.