Skip to main content

17 Nubrigyn Street Euchareena NSW 2866

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7.7 stars out of 10. Its BASIX certificate commits it to a 46,400 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 72 against 40.

Key features

Windows
14 windows and glazed doors: Aluminium B SG Clear; Al Thermally Broken B DG Air Fill Clear-Clear; Al Thermally Broken A DG Air Fill Clear-Clear
Wall insulation
R2.5
Roof and ceiling insulation
Ceiling R2.5, R5, roof Corrugated Iron Bulk+Foil, Reflective Side Down, Anti-glare Up R1.3, dark colour
Hot water
Electric heat pump with a performance of 21 to 25 STCs or better
Air conditioning and heating
1-phase airconditioning, non ducted (living area)

BASIX certificate

Water score
72 (target 40)
Thermal performance
Pass
Heating load
11 MJ/m² a year
Cooling load
10 MJ/m² a year
Hot water
Electric heat pump with a performance of 21 to 25 STCs or better
Rainwater tank
46,400 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Clothes line
Yes

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0 Vv Vv

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5 Vv Vv

Certificate 1733268S_03, issued 10 March 2025, from the council's DA documents.

NatHERS certificate

Star rating
7.7 stars
Rated with
BERS Pro v4.4.1.5 (3.21)
Rated on
28 Jul 2024
Wall insulation
R2.5
Ceiling insulation
R2.5, R5
Floor insulation
R2.5
Living room glazing by direction
N 7 m², E 2.7 m², W 4.4 m²
All glazing by direction
N 7 m², E 7.6 m², S 6.5 m², W 9.5 m²

Roof

  • Corrugated Iron Bulk+Foil, Reflective Side Down, Anti-glare Up R1.3, dark colour

Window types

  • ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7
  • ATB-004-01 B Al Thermally Broken B DG Air Fill Clear-Clear: U-value 3.6, SHGC 0.54
  • ATB-003-01 B Al Thermally Broken A DG Air Fill Clear-Clear: U-value 3.6, SHGC 0.47

Window schedule

  • Garage 1, window ALM-002-01 A: 1,200 × 1,800 mm facing E
  • Kitchen/Living, window ATB-004-01 B: 2,100 × 2,100 mm facing W
  • Kitchen/Living, window ATB-003-01 B: 1,500 × 900 mm facing N
  • Kitchen/Living, window ATB-003-01 B: 2,100 × 900 mm facing N
  • Kitchen/Living, window ATB-004-01 B: 600 × 1,800 mm facing N
  • Kitchen/Living, window ATB-003-01 B: 1,500 × 900 mm facing N
  • Kitchen/Living, window ATB-003-01 B: 1,500 × 900 mm facing N
  • Kitchen/Living, window ATB-003-01 B: 1,500 × 1,800 mm facing E
  • Bedroom 1, window ATB-003-01 B: 1,500 × 1,800 mm facing E
  • Bedroom 3, window ATB-003-01 B: 2,100 × 1,800 mm facing S
  • Unconditioned 1, window ATB-003-01 B: 2,100 × 900 mm facing W
  • Unconditioned 2, window ATB-003-01 B: 1,500 × 2,100 mm facing W
  • Unconditioned 3, window ATB-003-01 B: 900 × 600 mm facing S
  • Bedroom 2, window ATB-003-01 B: 1,200 × 1,800 mm facing S

Certificate 0009655044, issued 28 July 2024, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.