North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
86 Anita Avenue Lake Munmorah NSW 2259
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 6.6 kW of solar panels and a 5,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 100 against 70 for energy and 50 against 40 for water.
Key features
- Windows
- Up to aluminium frames 63.8 m², timber frames 1 m², single glazing 7.4 m², double glazing 57.4 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 100 (target 70)
- Water score
- 50 (target 40)
- Thermal performance
- Pass
- Materials score
- -47
- Heating load
- 28 MJ/m² a year
- Cooling load
- 22 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 236 m²
- Unconditioned floor area
- 29.6 m²
- Site area
- 570 m²
- Roof area
- 264 m²
- Garden area
- 291 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Solar panels
- 6.6 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Induction
- Maximum glazing
- aluminium frames 63.8 m², timber frames 1 m², single glazing 7.4 m², double glazing 57.4 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above open subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
- Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1829714S, issued 21 January 2026, from the council's DA documents.
Is this your home? Ask us to remove these details.