North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
7 Carlton Road Holgate NSW 2250
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 3,000 litre rainwater tank.
Key features
- Windows
- Up to aluminium frames 70 m², single glazing 12.5 m², double glazing 57.5 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 7 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by Probuild Project Management.
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -88
- Heating load
- 34 MJ/m² a year
- Cooling load
- 25 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 274.7 m²
- Unconditioned floor area
- 24 m²
- Site area
- 13,605 m²
- Roof area
- 503 m²
- Garden area
- 1,000 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 7 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 70 m², single glazing 12.5 m², double glazing 57.5 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1745711S_02, issued 1 May 2024, from the council's DA documents.