BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 10 kW of solar panels and a 30,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 100 against 70 for energy and 60 against 40 for water.
Key features
- Wall insulation
- External wall: insulated concrete form (ICF); frame: timber - H2 treated softwood (0.83 (or 3.00 including construction);rockwool batts, roll or pump-in + reflective foil in the cavity nil wall colour: Light (solar absorptance < 0.48))
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 100 (target 70)
- Water score
- 60 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Bedrooms
- 3
- Conditioned floor area
- 184 m²
- Unconditioned floor area
- 16 m²
- Site area
- 2,469 m²
- Roof area
- 155 m²
- Garden area
- 250 m²
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Solar panels
- 10 kW
- Rainwater tank
- 30,000 litres
- Fixtures
- Showerheads 4 star, toilets 6 star, kitchen taps 6 star, basin taps 6 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 6.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 6.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6.5 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: timber - H2 treated softwood (1 (or 1.6 including construction) (down);rockwool batts, roll or pump-in nil reflective foil facing the subfloor; subfloor wall insulation: <=R1.0)
- External wall: insulated concrete form (ICF); frame: timber - H2 treated softwood (0.83 (or 3.00 including construction);rockwool batts, roll or pump-in + reflective foil in the cavity nil wall colour: Light (solar absorptance < 0.48))
Certificate 1739697S, issued 13 March 2024, from the council's DA documents.