North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
51 Seventh Avenue Toukley NSW 2263
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 6.6 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 100 against 70 for energy and 43 against 40 for water.
Key features
- Windows
- Up to aluminium frames 25.3 m², timber frames 3.6 m², single glazing 28.9 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Electric heat pump with a performance of 21 to 25 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by Better Built Homes & Developments.
BASIX certificate
- Energy score
- 100 (target 70)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- -33
- Heating load
- 40 MJ/m² a year
- Cooling load
- 11 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 125.3 m²
- Unconditioned floor area
- 10.8 m²
- Site area
- 518 m²
- Roof area
- 249 m²
- Garden area
- 229 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric heat pump with a performance of 21 to 25 STCs or better
- Solar panels
- 6.6 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 25.3 m², timber frames 3.6 m², single glazing 28.9 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1824100S, issued 28 November 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.