BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to a 2,500 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor.

Key features

Windows
21 windows and glazed doors: Thermally Broken Aluminium Awning Window DG INSU564 - Argon; Timber Hinged Door DG 4PThrm/12/4EA; uPVC Sliding Window DG SOLOS OE Gy 6/12Ar/6 and 2 more types
Wall insulation
R2.5
Roof and ceiling insulation
Ceiling R5, R4, roof Waterproofing Membrane No Added Insulation, No air Gap, medium colour
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
70 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
1
Heating load
24 MJ/m² a year
Cooling load
26 MJ/m² a year
Bedrooms
3
Conditioned floor area
221.5 m²
Unconditioned floor area
14.1 m²
Site area
773 m²
Roof area
190 m²
Garden area
541 m²
Climate zone
NatHERS climate zone 15
Hot water
Gas instantaneous with a performance of 6 stars
Rainwater tank
2,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 6 star, basin taps 6 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
timber frames 77.5 m², single glazing 2.3 m², double glazing 75.2 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 1.5 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 1.5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 1.5 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 1.5 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (fibreglass batts or roll)
  • Floor: suspended floor above enclosed subfloor, fibre cement; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
  • Floor: suspended floor above open subfloor, fibre cement; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
  • Floor: above habitable rooms or mezzanine, fibre cement; frame: timber - H2 treated softwood (no added insulation)
  • External wall: concrete block/plasterboard; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil backed blanket.)

Certificate 1786668S, issued 10 March 2025, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
BERS Pro v5.2.4 (3.23)
Rated on
10 Mar 2025
Wall insulation
R2.5
Ceiling insulation
R5, R4
Floor insulation
R2.5, R1
LED downlights
49
Living room glazing by direction
N 10.3 m², E 32.8 m², S 2.4 m², W 5 m²
All glazing by direction
N 17.7 m², E 48.4 m², S 3.6 m², W 7.8 m²

Roof

  • Waterproofing Membrane No Added Insulation, No air Gap, medium colour
  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour

Window types

  • THC-023-011 Thermally Broken Aluminium Awning Window DG INSU564 - Argon: U-value 2.2, SHGC 0.2
  • STG-038-006 Timber Hinged Door DG 4PThrm/12/4EA: U-value 1.9, SHGC 0.24
  • DEC-003-023 uPVC Sliding Window DG SOLOS OE Gy 6/12Ar/6: U-value 1.9, SHGC 0.23
  • THC-033-011 Thermally Broken Aluminium Fixed Window DG INSU564 - Argon: U-value 1.9, SHGC 0.23
  • SOV-008-013 Composite Sliding Door DG 4SB60/14Ar/4Clr: U-value 1.7, SHGC 0.24

Window schedule

  • Bath, window THC-023-011: 600 × 1,800 mm facing N
  • Bedroom 02, window STG-038-006: 2,400 × 1,450 mm facing E
  • Bedroom 03, window STG-038-006: 2,400 × 1,450 mm facing E
  • Rumpus, window STG-038-006: 2,400 × 900 mm facing N
  • Rumpus, window DEC-003-023: 1,555 × 3,800 mm facing E
  • Rumpus, window THC-033-011: 1,500 × 800 mm facing S
  • Rumpus, window THC-033-011: 1,500 × 800 mm facing S
  • Kitchen/Living, window THC-033-011: 1,400 × 4,200 mm facing N
  • Kitchen/Living, window SOV-008-013: 2,400 × 5,600 mm facing E
  • Kitchen/Living, window SOV-008-013: 2,400 × 5,600 mm facing E
  • Kitchen/Living, window THC-033-011: 2,100 × 1,050 mm facing N
  • Kitchen/Living, window THC-033-011: 2,650 × 1,900 mm facing W
  • Entry, window THC-033-011: 2,400 × 500 mm facing N
  • Laundry, window THC-023-011: 1,500 × 800 mm facing S
  • Stair, window THC-033-011: 800 × 800 mm facing W
  • Master Stair, window THC-033-011: 2,400 × 900 mm facing N
  • Master Stair, window THC-033-011: 2,400 × 900 mm facing W
  • Master, window THC-033-011: 1,500 × 1,200 mm facing N
  • Master, window DEC-003-023: 1,500 × 4,200 mm facing E
  • Study, window THC-033-011: 1,350 × 1,700 mm facing E
  • Ensuite, window THC-023-011: 1,500 × 800 mm facing N

Certificate 0011773652, issued 10 March 2025, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.