Skip to main content

42 North Avoca Parade North Avoca NSW 2260

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 1 kW of solar panels and a 7,500 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 81 against 70.

Key features

Windows
29 windows and glazed doors: Timber A SG Clear; Timber B SG Clear; Timber B SG High Solar Gain Low-E and 2 more types
Wall insulation
R4.8
Roof and ceiling insulation
Ceiling R4.0, R4.5, roof as_ROOF-A001 #E015 © 29 deg steel roof + Anticon R2.0 insul with R6.0 bulk insul + CFC ceiling under R8.0, medium colour
Hot water
Electric heat pump
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom); Heat pump hydronic system (living area)

BASIX certificate

Energy score
81 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-52
Heating load
28 MJ/m² a year
Cooling load
22 MJ/m² a year
Bedrooms
4
Conditioned floor area
255.6 m²
Unconditioned floor area
14.2 m²
Site area
632 m²
Roof area
279 m²
Garden area
180 m²
Climate zone
NatHERS climate zone 15
Hot water
Electric heat pump
Solar panels
1 kW
Rainwater tank
7,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 3 star, basin taps 5 star
LED lighting
Yes
Maximum glazing
timber frames 120.9 m², single glazing 4.3 m², double glazing 116.6 m²

Heating

  • Living area: heat pump hydronic system; Energy rating: n/a
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground (not specified)
  • Floor: suspended floor above enclosed subfloor, hard wood; frame: timber - untreated softwood (not specified)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (not specified)
  • Floor: above habitable rooms or mezzanine, hard wood; frame: timber - untreated softwood (not specified)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (not specified)
  • Garage floor: concrete slab on ground (not specified)
  • External wall: reverse brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (fibreglass batts or roll)
  • External wall: concrete block/plasterboard; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)

Certificate 1376200S, issued 15 November 2023, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
AccuRate Home v1.3.3.23
Rated on
15 Nov 2023
Wall insulation
R4.8
Ceiling insulation
R4.0, R4.5
Floor insulation
R4.8, R2.0, R4.0, R4.5
Living room glazing by direction
NE 3.9 m², SE 38 m², SW 1.2 m², NW 27.4 m²
All glazing by direction
NE 21.8 m², SE 55.9 m², SW 3.8 m², NW 39.4 m²

Roof

  • as_ROOF-A001 #E015 © 29 deg steel roof + Anticon R2.0 insul with R6.0 bulk insul + CFC ceiling under R8.0, medium colour
  • as_ROOF-B013.rof #1001 © Concrete slab 170mm - Drained Tile walking surface - no insulation - no Ceiling under, medium colour

Window types

  • TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
  • TIM-002-01 W Timber B SG Clear: U-value 5.4, SHGC 0.63
  • TIM-002-03 W Timber B SG High Solar Gain Low-E: U-value 4.3, SHGC 0.5
  • TIM-006-03 W Timber B DG Argon Fill High Solar Gain low-E - Clear: U-value 2, SHGC 0.31
  • TIM-005-03 W Timber A DG Argon Fill High Solar Gain low-E - Clear: U-value 2, SHGC 0.25

Window schedule

  • Laundry, window TIM-002-01 W: 2,300 × 1,800 mm facing NE
  • B2, window TIM-002-03 W: 2,499 × 300 mm facing SW
  • B2, window TIM-005-03 W: 2,100 × 1,300 mm facing NW
  • E2, window TIM-005-03 W: 400 × 450 mm facing SW
  • B3, window TIM-005-03 W: 400 × 450 mm facing SW
  • B3, window TIM-006-03 W: 2,100 × 1,800 mm facing NE
  • E3, window TIM-005-03 W: 400 × 450 mm facing SW
  • H3, window TIM-006-03 W: 2,100 × 2,699 mm facing NE
  • H3, window TIM-006-03 W: 1,599 × 2,699 mm facing NE
  • Rumpus, window TIM-006-03 W: 2,400 × 5,699 mm facing SE
  • Rumpus, window TIM-002-03 W: 2,100 × 900 mm facing NW
  • Rumpus, window TIM-002-03 W: 1,000 × 900 mm facing NW
  • E4, window TIM-005-03 W: 400 × 450 mm facing SW
  • B4, window TIM-002-03 W: 2,099 × 300 mm facing SW
  • B4, window TIM-005-03 W: 2,100 × 1,300 mm facing NW
  • Pantry, window TIM-006-03 W: 800 × 450 mm facing SE
  • WC, window TIM-001-01 W: 400 × 450 mm facing SW
  • Kitchen Living, window TIM-006-03 W: 500 × 2,600 mm facing NE
  • Kitchen Living, window TIM-006-03 W: 500 × 2,600 mm facing NE
  • Kitchen Living, window TIM-006-03 W: 500 × 2,600 mm facing NE
  • Kitchen Living, window TIM-006-03 W: 3,000 × 8,099 mm facing SE
  • Kitchen Living, window TIM-002-03 W: 4,100 × 300 mm facing SW
  • Kitchen Living, window TIM-005-03 W: 3,000 × 1,999 mm facing NW
  • Kitchen Living, window TIM-006-03 W: 3,000 × 6,200 mm facing NW
  • Ensuite Master, window TIM-002-03 W: 1,000 × 300 mm facing SW
  • Ensuite Master, window TIM-002-03 W: 2,200 × 1,899 mm facing SE
  • Master Study Robe, window TIM-006-03 W: 2,200 × 4,200 mm facing SE
  • Master Study Robe, window TIM-002-03 W: 2,200 × 1,899 mm facing SE
  • Master Study Robe, window TIM-006-03 W: 2,100 × 3,100 mm facing NW

Certificate 0009067869, issued 15 November 2023, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related