37 Mackenzie Avenue Woy Woy NSW 2256

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to a 2,500 litre rainwater tank.

Key features

Windows
29 windows and glazed doors: Aluminium A SG Clear; Composite A DG Air Fill High Solar Gain low-E -Clear; Composite B DG Air Fill High Solar Gain low-E -Clear
Wall insulation
Not specified
Roof and ceiling insulation
Roof Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 0.00, medium colour
Hot water
Gas instantaneous with a performance of 7 stars
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

Built by Montgomery Homes.

BASIX certificate

Energy score
70 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
19 MJ/m² a year
Cooling load
30 MJ/m² a year
Bedrooms
5
Conditioned floor area
212.9 m²
Unconditioned floor area
22 m²
Site area
544 m²
Roof area
194 m²
Garden area
194 m²
Climate zone
NatHERS climate zone 15
Hot water
Gas instantaneous with a performance of 7 stars
Rainwater tank
2,500 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 53.3 m², double glazing 53.3 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: suspended floor above open subfloor, treated softwood; frame: timber - H2 treated softwood (not specified)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (not specified)
  • Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (not specified)
  • Garage floor: concrete slab on ground (not specified)
  • External wall: AAC veneer; frame: timber - H2 treated softwood (not specified)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (not specified)
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (not specified)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (not specified)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: not specified; roof: not specified.)

Certificate 1823765S, issued 27 November 2025, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
Hero 4.1
Rated on
27 Nov 2025
Living room glazing by direction
N 14.2 m², E 2.4 m², S 8.7 m², W 6.5 m²
All glazing by direction
N 16.4 m², E 10.2 m², S 14.8 m², W 11.9 m²

Roof

  • Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 0.00, medium colour

Window types

  • ALM-001-01 A Aluminium A SG Clear: U-value 6.7, SHGC 0.57
  • CMP-003-03 I Composite A DG Air Fill High Solar Gain low-E -Clear: U-value 3.4, SHGC 0.47
  • CMP-004-03 I Composite B DG Air Fill High Solar Gain low-E -Clear: U-value 3.4, SHGC 0.53

Window schedule

  • BATH, window CMP-004-03 I: 1,500 × 900 mm facing W
  • BED 1, window CMP-004-03 I: 600 × 1,800 mm facing N
  • BED 1, window CMP-004-03 I: 600 × 1,800 mm facing N
  • BED 2, window CMP-004-03 I: 1,000 × 1,800 mm facing E
  • BED 3, window CMP-004-03 I: 1,000 × 1,800 mm facing E
  • BED 4, window CMP-004-03 I: 600 × 2,700 mm facing S
  • BED 4, window CMP-004-03 I: 600 × 2,700 mm facing S
  • BED 4, window CMP-003-03 I: 600 × 600 mm facing E
  • BED 4, window CMP-003-03 I: 600 × 600 mm facing E
  • BED 4, window CMP-004-03 I: 600 × 1,600 mm facing E
  • BED 4 ENS, window CMP-004-03 I: 900 × 900 mm facing E
  • ENS, window CMP-004-03 I: 1,500 × 900 mm facing W
  • GUEST ROOM, window CMP-003-03 I: 1,800 × 1,600 mm facing S
  • KITCHEN/LIVING, window CMP-004-03 I: 600 × 1,600 mm facing E
  • KITCHEN/LIVING, window CMP-004-03 I: 600 × 2,400 mm facing E
  • KITCHEN/LIVING, window CMP-004-03 I: 750 × 1,200 mm facing W
  • KITCHEN/LIVING, window CMP-003-03 I: 1,800 × 850 mm facing N
  • KITCHEN/LIVING, window CMP-003-03 I: 1,800 × 850 mm facing N
  • KITCHEN/LIVING, window CMP-004-03 I: 2,100 × 5,300 mm facing N
  • KITCHEN/LIVING, window CMP-003-03 I: 1,800 × 850 mm facing W
  • KITCHEN/LIVING, window CMP-003-03 I: 1,800 × 850 mm facing W
  • L'DRY, window ALM-001-01 A: 2,100 × 820 mm facing E
  • POW 1, window CMP-004-03 I: 900 × 600 mm facing W
  • RUMPUS, window CMP-004-03 I: 1,050 × 1,200 mm facing W
  • RUMPUS, window CMP-004-03 I: 2,100 × 3,500 mm facing S
  • RUMPUS, window CMP-004-03 I: 370 × 3,580 mm facing S
  • RUMPUS, window CMP-004-03 I: 600 × 2,200 mm facing W
  • THEATRE, window CMP-004-03 I: 600 × 1,800 mm facing W
  • THEATRE, window CMP-004-03 I: 600 × 1,800 mm facing W

Certificate HR-HN0CFA-01, issued 27 November 2025, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.