North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
33 Thelma Street Long Jetty NSW 2261
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 3 kW of solar panels and a 2,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 84 against 70 for energy and 45 against 40 for water.
Key features
- Windows
- Up to aluminium frames 87.4 m², single glazing 8.2 m², double glazing 79.2 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric storage
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 84 (target 70)
- Water score
- 45 (target 40)
- Thermal performance
- Pass
- Materials score
- -39
- Heating load
- 33 MJ/m² a year
- Cooling load
- 17 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 309.3 m²
- Unconditioned floor area
- 17.5 m²
- Site area
- 592 m²
- Roof area
- 310 m²
- Garden area
- 150 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric storage
- Solar panels
- 3 kW
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 87.4 m², single glazing 8.2 m², double glazing 79.2 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above open subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1807190S_02, issued 5 August 2025, from the council's DA documents.