North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
31 Elizabeth Drive Noraville NSW 2263
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 5 kW of solar panels and a 5,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 90 against 70 for energy and 43 against 40 for water.
Key features
- Windows
- 30 windows and glazed doors: Thermally Broken Aluminium Hinged Door DG AGG MAX LI 6/12/6; Thermally Broken Aluminium Sliding Door DG 5Clr/8Ar90/5LB; Thermally Broken Aluminium Fixed Window DG AGG MAX Clr 6/12/6 and 1 more types
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R6, R5, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
- Hot water
- Electric boosted solar with a performance of 15 to 20 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 90 (target 70)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- -68
- Heating load
- 31 MJ/m² a year
- Cooling load
- 20 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 370 m²
- Unconditioned floor area
- 6.4 m²
- Site area
- 639 m²
- Roof area
- 205 m²
- Garden area
- 182 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric boosted solar with a performance of 15 to 20 STCs or better
- Solar panels
- 5 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 167.2 m², double glazing 167.2 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (polystyrene)
- Floor: above habitable rooms or mezzanine, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: reverse brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: concrete block/plasterboard; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1803065S, issued 7 July 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.2.4 (3.23)
- Rated on
- 07 Jul 2025
- Wall insulation
- R2.5
- Ceiling insulation
- R6, R5
- Floor insulation
- R2.5, R3.4, R5
- LED downlights
- 66
- Living room glazing by direction
- N 6.3 m², E 29.9 m², W 14.2 m²
- All glazing by direction
- N 44.3 m², E 69.8 m², S 18.7 m², W 34.4 m²
Roof
- Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
- Corrugated Iron Timber Frame No Insulation, Only an Air Gap, medium colour
- Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, light colour
Window types
- CAP-115-061 Thermally Broken Aluminium Hinged Door DG AGG MAX LI 6/12/6: U-value 2.5, SHGC 0.2
- CAP-584-009 Thermally Broken Aluminium Sliding Door DG 5Clr/8Ar90/5LB: U-value 2.3, SHGC 0.46
- CAP-148-039 Thermally Broken Aluminium Fixed Window DG AGG MAX Clr 6/12/6: U-value 1.8, SHGC 0.24
- CAP-520-018 Thermally Broken Aluminium Double Hung Window DG AGG MAX Clr 6/12/4: U-value 2.3, SHGC 0.21
Window schedule
- Laundry, window CAP-115-061: 2,400 × 900 mm facing S
- Gym / Wellness, window CAP-584-009: 3,375 × 2,300 mm facing W
- Gym / Wellness, window CAP-148-039: 900 × 2,380 mm facing N
- Sitting, window CAP-148-039: 900 × 2,380 mm facing N
- Sitting, window CAP-584-009: 2,700 × 4,230 mm facing E
- Hallway, window CAP-148-039: 2,475 × 4,710 mm facing N
- Hallway, window CAP-115-061: 3,375 × 1,245 mm facing N
- Kitchen/Living1, window CAP-148-039: 900 × 3,500 mm facing N
- Kitchen/Living1, window CAP-148-039: 900 × 3,500 mm facing N
- Kitchen/Living1, window CAP-584-009: 2,700 × 5,835 mm facing E
- Kitchen/Living1, window CAP-584-009: 2,700 × 5,250 mm facing E
- Kitchen/Living1, window CAP-584-009: 2,700 × 5,250 mm facing W
- Butlers, window CAP-584-009: 600 × 1,735 mm facing S
- Bedroom 3, window CAP-148-039: 1,500 × 2,000 mm facing S
- Bedroom 3, window CAP-520-018: 1,500 × 900 mm facing S
- Study, window CAP-520-018: 1,500 × 900 mm facing S
- Study, window CAP-148-039: 1,500 × 910 mm facing S
- Upper Hall, window CAP-148-039: 2,900 × 1,220 mm facing W
- Upper Hall, window CAP-148-039: 1,900 × 4,710 mm facing N
- Bedroom 5, window CAP-584-009: 2,700 × 4,230 mm facing E
- Bed 5 Ensuite, window CAP-520-018: 1,800 × 900 mm facing W
- Bunk Room, window CAP-520-018: 2,500 × 900 mm facing W
- Bunk Room, window CAP-148-039: 2,500 × 2,000 mm facing W
- Bedroom 4, window CAP-520-018: 1,800 × 900 mm facing S
- Bedroom 4, window CAP-148-039: 1,800 × 2,000 mm facing S
- Bed 4 Ensuite, window CAP-520-018: 1,800 × 900 mm facing S
- Upper Study, window CAP-584-009: 2,700 × 3,300 mm facing N
- Upper Study, window CAP-584-009: 2,700 × 2,670 mm facing E
- Main Bedroom, window CAP-584-009: 2,700 × 3,650 mm facing E
- Main Ensuite, window CAP-520-018: 1,800 × 900 mm facing S
Certificate 0012035127, issued 7 July 2025, from the council's DA documents. Verify this certificate