27 Rushby Street Bateau Bay NSW 2261
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 3 kW of solar panels and a 6,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 75 against 70.
Key features
- Windows
- 23 windows and glazed doors: Aluminium B DG Argon Fill High Solar Gain low-E -Clear; Aluminium A DG Argon Fill High Solar Gain low-E -Clear; Aluminium B SG Clear and 1 more types
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R6.0, R7.3, roof Cont:Attic-Continuous 1.3, medium colour
- Hot water
- Gas instantaneous
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Raybal Constructions.
BASIX certificate
- Energy score
- 75 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -56
- Heating load
- 32 MJ/m² a year
- Cooling load
- 19 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 178.7 m²
- Unconditioned floor area
- 58.8 m²
- Site area
- 566 m²
- Roof area
- 352 m²
- Garden area
- 180 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Gas instantaneous
- Solar panels
- 3 kW
- Rainwater tank
- 6,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 57.1 m², single glazing 2.9 m², double glazing 54.3 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (polyurethane)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1776300S, issued 5 December 2024, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 5 Dec 2024
- Wall insulation
- R2.5
- Ceiling insulation
- R6.0, R7.3
- Floor insulation
- R2.5, R2.0, R0.6
- Living room glazing by direction
- N 14.9 m², S 12.5 m²
- All glazing by direction
- N 29.4 m², E 9.4 m², S 14 m², W 4.4 m²
Roof
- Cont:Attic-Continuous 1.3, medium colour
- Framed:Flat - Flat Framed (Metal Deck) 0.0, medium colour
- Cont:Attic-Continuous 0.0, medium colour
Window types
- ALM-006-03 A Aluminium B DG Argon Fill High Solar Gain low-E -Clear: U-value 4.1, SHGC 0.52
- ALM-005-03 A Aluminium A DG Argon Fill High Solar Gain low-E -Clear: U-value 4.1, SHGC 0.47
- ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7
- STG-057-35 W Prem Siteline Clad-Tim w Al Sliding Door DG 4-8-4ET: U-value 2.4, SHGC 0.52
Window schedule
- Kit/Liv/Din, window STG-057-35 W: 2,400 × 4,000 mm facing S
- Kit/Liv/Din, window ALM-006-03 A: 2,400 × 1,210 mm facing S
- Kit/Liv/Din, window ALM-006-03 A: 935 × 2,220 mm facing N
- Kit/Liv/Din, window ALM-006-03 A: 935 × 2,220 mm facing N
- Kit/Liv/Din, window STG-057-35 W: 2,400 × 4,460 mm facing N
- Foyer, window ALM-006-03 A: 2,400 × 575 mm facing N
- Foyer, window ALM-005-03 A: 2,400 × 1,200 mm facing N
- Foyer, window ALM-006-03 A: 2,400 × 575 mm facing N
- Bedroom 1, window ALM-005-03 A: 2,400 × 900 mm facing N
- Bedroom 1, window ALM-005-03 A: 2,400 × 1,600 mm facing N
- Bedroom 1, window ALM-005-03 A: 2,400 × 900 mm facing N
- ENS, window ALM-005-03 A: 1,460 × 610 mm facing E
- Laundry, window ALM-005-03 A: 860 × 610 mm facing E
- Laundry, window ALM-002-01 A: 850 × 820 mm facing E
- Media Room, window ALM-005-03 A: 860 × 2,410 mm facing E
- Bedroom 2, window ALM-006-03 A: 1,030 × 1,570 mm facing E
- Bathroom, window ALM-006-03 A: 610 × 1,510 mm facing E
- Bedroom 3, window ALM-006-03 A: 1,030 × 1,570 mm facing E
- Study, window ALM-005-03 A: 1,460 × 750 mm facing E
- Garage, window ALM-002-01 A: 610 × 2,410 mm facing S
- Garage, window ALM-002-01 A: 850 × 820 mm facing N
- Hallway, window ALM-005-03 A: 1,800 × 1,210 mm facing W
- Hallway, window ALM-005-03 A: 1,800 × 1,210 mm facing W
Certificate XM7RKKUBC0, issued 5 December 2024, from the council's DA documents. Verify this certificate