North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
26 Bambury Avenue Summerland Point NSW 2259
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 5.3 stars out of 10. Its BASIX certificate commits it to 1 kW of solar panels and a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 59 against 50 for energy and 51 against 40 for water.
Key features
- Windows
- 37 windows and glazed doors: Trend Al Sliding Window SG 3Clr; Signature Entry Door 125 SG 6.38CPClr; Trend Crestlite Center Glazed Window SG 6EA and 4 more types
- Wall insulation
- R2.7
- Roof and ceiling insulation
- Ceiling R5, R4, roof Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.8, medium colour
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 1-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 59 (target 50)
- Water score
- 51 (target 40)
- Thermal performance
- Pass
- Heating load
- 55 MJ/m² a year
- Cooling load
- 24 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 301.7 m²
- Unconditioned floor area
- 21.5 m²
- Site area
- 1,077 m²
- Roof area
- 250 m²
- Garden area
- 100 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Solar panels
- 1 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Clothes line
- Yes
Heating
- Living area: 1-phase airconditioning; Energy rating: 6 star (average zone)
- Bedroom: 1-phase airconditioning; Energy rating: 6 star (average zone)
Cooling
- Living area: 1-phase airconditioning; Energy rating: 6 star (average zone)
- Bedroom: 1-phase airconditioning; Energy rating: 6 star (average zone)
Certificate 1392187S, issued 16 August 2023, from the council's DA documents.
NatHERS certificate
- Star rating
- 5.3 stars
- Rated with
- BERS Pro v4.4.1.5 (3.21)
- Rated on
- 16 Aug 2023
- Wall insulation
- R2.7
- Ceiling insulation
- R5, R4
- Floor insulation
- R4, R3
- Living room glazing by direction
- N 16.6 m², E 1.8 m², S 6.1 m², W 2.7 m²
- All glazing by direction
- N 33.1 m², E 17.8 m², S 17.1 m², W 14.9 m²
Roof
- Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.8, medium colour
Window types
- TND-001-01 A Trend Al Sliding Window SG 3Clr: U-value 6.4, SHGC 0.73
- BRD-083-04 A Signature Entry Door 125 SG 6.38CPClr: U-value 4.2, SHGC 0.51
- TND-032-02 A Trend Crestlite Center Glazed Window SG 6EA: U-value 4.3, SHGC 0.61
- TND-002-32 A Trend Al Awning Window SG 638ComPlsClr: U-value 4.9, SHGC 0.53
- BRZ-003-13 A 52mm Altair Louvre Window System SG 6LE: U-value 4.3, SHGC 0.57
- TND-006-02 A Xtreme Sliding Door SG 5mm Energy Advantage: U-value 4.2, SHGC 0.6
- TND-022-03 A Trend Al Bi-Fold Door SG 6.38CP: U-value 4.5, SHGC 0.37
Window schedule
- Garage, window TND-001-01 A: 1,200 × 1,800 mm facing E
- Entry Hallway, window BRD-083-04 A: 2,400 × 1,200 mm facing S
- Entry Hallway, window TND-032-02 A: 2,400 × 500 mm facing S
- Entry Hallway, window TND-032-02 A: 2,400 × 500 mm facing S
- Entry Hallway, window TND-002-32 A: 1,500 × 900 mm facing W
- Entry Hallway, window TND-002-32 A: 1,500 × 900 mm facing W
- Entry Hallway, window BRD-083-04 A: 2,400 × 820 mm facing W
- Entry Hallway, window BRZ-003-13 A: 1,200 × 2,700 mm facing E
- Entry Hallway, window TND-032-02 A: 1,800 × 1,200 mm facing N
- Powder Room 1, window TND-002-32 A: 1,500 × 900 mm facing W
- Laundry, window TND-002-32 A: 1,500 × 900 mm facing W
- Bedroom 4, window TND-002-32 A: 900 × 1,200 mm facing S
- Bedroom 4, window BRZ-003-13 A: 600 × 1,800 mm facing E
- Bedroom 4, window BRZ-003-13 A: 600 × 1,800 mm facing E
- Activity Room, window TND-002-32 A: 1,200 × 1,800 mm facing W
- Activity Room, window TND-006-02 A: 2,400 × 3,600 mm facing N
- WC, window TND-002-32 A: 1,200 × 900 mm facing E
- Bathroom, window BRZ-003-13 A: 1,500 × 1,200 mm facing E
- Bedroom 3, window TND-002-32 A: 1,200 × 1,800 mm facing E
- Bedroom 2, window TND-006-02 A: 2,400 × 2,400 mm facing N
- Bedroom 2, window TND-002-32 A: 1,200 × 1,800 mm facing E
- Kitchen/Living, window BRZ-003-13 A: 1,500 × 1,200 mm facing N
- Kitchen/Living, window BRZ-003-13 A: 1,500 × 1,200 mm facing N
- Kitchen/Living, window TND-022-03 A: 2,400 × 5,400 mm facing N
- Kitchen/Living, window BRZ-003-13 A: 600 × 1,500 mm facing E
- Kitchen/Living, window BRZ-003-13 A: 600 × 1,500 mm facing E
- Kitchen/Living, window BRZ-003-13 A: 600 × 1,500 mm facing W
- Kitchen/Living, window BRZ-003-13 A: 1,200 × 1,500 mm facing W
- Pantry, window BRZ-003-13 A: 600 × 2,600 mm facing S
- Powder Room 2, window TND-002-32 A: 900 × 900 mm facing S
- Bedroom 1, window BRZ-003-13 A: 2,100 × 600 mm facing E
- Bedroom 1, window TND-001-01 A: 1,200 × 1,800 mm facing W
- WIR, window BRZ-003-13 A: 1,500 × 900 mm facing S
- Ensuite, window BRZ-003-13 A: 600 × 1,500 mm facing S
- Ensuite, window BRZ-003-13 A: 900 × 600 mm facing W
- Rumpus, window BRZ-003-13 A: 1,500 × 1,200 mm facing S
- Rumpus, window TND-006-02 A: 2,400 × 1,800 mm facing S
Certificate 0008812364-01, issued 16 August 2023, from the council's DA documents.